<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Strumenti di misurazione e test della Luce - Senseca Italy Srl</title>
	<atom:link href="https://environmental.senseca.com/it/misura/luce/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/it/misura/luce/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Fri, 14 Mar 2025 17:09:29 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>Strumenti di misurazione e test della Luce - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/misura/luce/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LP471UVBC &#8211; Sonda Radiometrica UV-BC</title>
		<link>https://environmental.senseca.com/it/prodotto/lp471uvbc-sonda-radiometrica-uv-bc/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Fri, 05 Mar 2021 11:24:48 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uvbc-sonda-radiometrica-uv-bc/</guid>

					<description><![CDATA[<p>Sonda radiometrica per la misura dell’irradiamento nel campo spettrale UV-BC 210 nm…355 nm, picco a 265 nm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lp471uvbc-sonda-radiometrica-uv-bc/">LP471UVBC &#8211; Sonda Radiometrica UV-BC</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>LP471UVBC è una <strong>sonda radiometrica per la misurazione dell&#8217;irradiamento (W/m²) nell&#8217;campo spettrale 210&#8230;355 nm</strong> con picco a 265 nm. È dotata di un connettore con modulo SICRAM e di un cavo di 2 m</p>
<p>La sonda è composta da un fotodiodo con un filtro appropriato ed è dotata di un diffusore per una corretta misurazione secondo la legge del coseno. Viene tipicamente utilizzata nella <strong>verifica delle lampade germicide utilizzate negli impianti di sterilizzazione</strong> che lavorano con LED come sorgenti di luce UV.</p>
<p>La sonda è disponibile anche già combinata in kit pronti all&#8217;uso. A seconda delle vostre esigenze, potete scegliere una versione base composta dalla sonda e dal nostro luxmetro HD2302.0 per misurare e leggere semplicemente i valori (UVBC-CK02-ACC). Per una versione più avanzata con funzione di data logging, la sonda è abbinata al nostro datalogger luxmetro portatile HD2102.2 (UVBC-CK01-ACC).</p>
<p>Per entrambe le soluzioni, la correttezza delle vostre misure è assicurata anche dal certificato di Taratura ISO 17025 rilasciato nel nostro laboratorio di foto-radiometria accreditato.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lp471uvbc-sonda-radiometrica-uv-bc/">LP471UVBC &#8211; Sonda Radiometrica UV-BC</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CPM12AA4&#8230; Serie &#8211; Cavo 4 poli connettore M12</title>
		<link>https://environmental.senseca.com/it/prodotto/cpm12aa4-serie-cavo-4-poli-connettore-m12/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:21:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/cpm12aa4-serie-cavo-4-poli-connettore-m12/</guid>

					<description><![CDATA[<p>Cavo a 4 poli. Connettore M12 4 poli da un lato, fili aperti dall’altro</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa4-serie-cavo-4-poli-connettore-m12/">CPM12AA4&#8230; Serie &#8211; Cavo 4 poli connettore M12</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cavo a 4 poli. Connettore M12 4 poli da un lato, fili aperti dall’altro.</p>
<p>Lunghezze disponibili: 5 m (CPM12AA4.5) e 10 m ( CPM12AA4.10).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa4-serie-cavo-4-poli-connettore-m12/">CPM12AA4&#8230; Serie &#8211; Cavo 4 poli connettore M12</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPSG &#8211; Cartuccia per Silica-Gel</title>
		<link>https://environmental.senseca.com/it/prodotto/lpsg-cartuccia-per-silica-gel/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lpsg-cartuccia-per-silica-gel/</guid>

					<description><![CDATA[<p>Cartuccia per contenere i cristalli di silica-gel completa di O-ring e tappo. Ricambio.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsg-cartuccia-per-silica-gel/">LPSG &#8211; Cartuccia per Silica-Gel</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cartuccia per contenere i cristalli di silica-gel completa di O-ring e tappo. Ricambio.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsg-cartuccia-per-silica-gel/">LPSG &#8211; Cartuccia per Silica-Gel</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CPM12AA8&#8230; Serie &#8211; Cavo 8 poli</title>
		<link>https://environmental.senseca.com/it/prodotto/cpm12aa8-serie-8-pole-m12-connector-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:21:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/cpm12aa8-serie-cavo-8-poli-connettore-m12/</guid>

					<description><![CDATA[<p>Cavo a 8 poli. Connettore M12 8 poli da un lato, fili aperti dall’altro</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa8-serie-8-pole-m12-connector-2/">CPM12AA8&#8230; Serie &#8211; Cavo 8 poli</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cavo a 8 poli. Connettore M12 8 poli da un lato, fili aperti dall’altro (non adatto per sensori con uscita RS485 e SDI-12).</p>
<p>Lunghezze disponibili :  5 m ( CPM12AA8.5 ) e 10 m ( CPM12AA8.10).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa8-serie-8-pole-m12-connector-2/">CPM12AA8&#8230; Serie &#8211; Cavo 8 poli</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPSP2 &#8211; Schermo Protezione Piranometri</title>
		<link>https://environmental.senseca.com/it/prodotto/lpsp2-schermo-protezione/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lpsp2-schermo-protezione/</guid>

					<description><![CDATA[<p>Ricambio schermo protezione</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsp2-schermo-protezione/">LPSP2 &#8211; Schermo Protezione Piranometri</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Ricambio schermo di protezione per piranometro LPPYRA03 e albedometro LPPYRA06.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsp2-schermo-protezione/">LPSP2 &#8211; Schermo Protezione Piranometri</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPSP3 &#8211; Schermo Protezione Piranometri</title>
		<link>https://environmental.senseca.com/it/prodotto/lpsp2-schermo-protezione-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lpsp2-schermo-protezione-2/</guid>

					<description><![CDATA[<p>Ricambio schermo protezione</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsp2-schermo-protezione-2/">LPSP3 &#8211; Schermo Protezione Piranometri</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Ricambio per schermo di protezione per piranometro inferiore dell’LPPYRA05.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsp2-schermo-protezione-2/">LPSP3 &#8211; Schermo Protezione Piranometri</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPSP4 &#8211; Flangia Supporto</title>
		<link>https://environmental.senseca.com/it/prodotto/lpsp4-flangia-supporto/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lpsp4-flangia-supporto/</guid>

					<description><![CDATA[<p>Flangia per il fissaggio di piranometri su un piano.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsp4-flangia-supporto/">LPSP4 &#8211; Flangia Supporto</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Flangia per il fissaggio di piranometri su un piano.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lpsp4-flangia-supporto/">LPSP4 &#8211; Flangia Supporto</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPPYRA12&#8230; Serie &#8211; Piranometro Spectrally Flat Classe B con Anello di Schermo</title>
		<link>https://environmental.senseca.com/it/prodotto/lppyra12-piranometro-spectrally-flat-classe-b-con-anello-di-schermo/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lppyra12-piranometro-spectrally-flat-classe-b-con-anello-di-schermo/</guid>

					<description><![CDATA[<p>Piranometro Spectrally Flat Class B (first class) secondo ISO 9060:2018 con anello di schermo per la misura della sola componente diffusa della radiazione solare.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lppyra12-piranometro-spectrally-flat-classe-b-con-anello-di-schermo/">LPPYRA12&#8230; Serie &#8211; Piranometro Spectrally Flat Classe B con Anello di Schermo</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>LPPYRA12 sono piranometri classificati come <strong>Spectrally Flat Class B</strong> (Prima Classe) secondo la norma ISO 9060:2018 e in conformità alle raccomandazioni del WMO.</p>
<p>Grazie all&#8217;<strong>anello di schermo</strong> per la componente diretta, la serie di piranometri LPPYRA12 consente di misurare la sola componente diffusa della radiazione solare.</p>
<p>Le versioni disponibili sono cinque:</p>
<ul>
<li><strong>LPPYRA12</strong> &#8211; PASSIVO</li>
<li><strong>LPPYRA12AC</strong> &#8211; ATTIVO con uscita in CORRENTE 4..20 mA. Campo di misura 0&#8230;2000 W/m² o 0&#8230;4000 W/m² (LPPYRA12AC4)</li>
<li><strong>LPPYRA12ACS &#8211; </strong>Doppia uscita in corrente 4&#8230;20 mA e seriale RS485 con protocollo MODBUS-RTU. Campo di misura 0&#8230;2000 W/m² o 0&#8230;4000 W/m² (LPPYRA12ACS4)</li>
<li><strong>LPPYRA12AV</strong> &#8211; ATTIVO con uscita in TENSIONE 0&#8230;1 o 0&#8230;5 o 0&#8230;10 V da definire al momento dell’ordine. Campo di misura 0&#8230;2000 W/m² o 0&#8230;4000 W/m² (LPPYRA12AV4)</li>
<li><strong>LPPYRA12S</strong> &#8211; Con uscita RS485 Modbus-RTU</li>
<li><strong>LPPYRA12S12</strong> &#8211; Con uscita SDI-12.</li>
</ul>
<p>&nbsp;</p>
<p hidden="">LPPYRA12, LPPYRA12AC, LPPYRA12AC4, LPPYRA12AV, LPPYRA12AV4, LPPYRA12S, LPPYRA12S12</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lppyra12-piranometro-spectrally-flat-classe-b-con-anello-di-schermo/">LPPYRA12&#8230; Serie &#8211; Piranometro Spectrally Flat Classe B con Anello di Schermo</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPPYRA05 &#8211; Albedometro Spectrally Flat Classe B</title>
		<link>https://environmental.senseca.com/it/prodotto/lppyra05-albedometro-spectrally-flat-classe-b/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lppyra05-albedometro-spectrally-flat-classe-b/</guid>

					<description><![CDATA[<p>Albedometro composto da 2 piranometri Spectrally Flat Class B (prima classe) secondo ISO 9060:2018.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lppyra05-albedometro-spectrally-flat-classe-b/">LPPYRA05 &#8211; Albedometro Spectrally Flat Classe B</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Si prega di notare che questo articolo è fuori produzione.</p>
<p>Il corrispondente nuovo prodotto è <a href="https://environmental.senseca.com/it/prodotto/lps05-albedometro-spectrally-flat-classe-b/">LPS05 – Albedometro Spectrally Flat Classe B.</a></p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lppyra05-albedometro-spectrally-flat-classe-b/">LPPYRA05 &#8211; Albedometro Spectrally Flat Classe B</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2021T Serie &#8211; Trasmettitori Fotometrici e Radiometrici</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2021t-serie-trasmettitori-fotometrici-e-radiometrici/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2021t-serie-trasmettitori-fotometrici-e-radiometrici/</guid>

					<description><![CDATA[<p>Trasmettitori fotometrici/radiometrici per misurare l'illuminamento, l'irradiamento e la luminanza all'esterno</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2021t-serie-trasmettitori-fotometrici-e-radiometrici/">HD2021T Serie &#8211; Trasmettitori Fotometrici e Radiometrici</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Si prega di notare che il modello HD2021T<strong>2</strong> è fuori produzione.</p>
<p>La serie di trasmettitori <strong>HD2021T</strong> permette di convertire le grandezze fotometriche e radiometriche quali l’illuminamento (Lux) e l’irradiamento (W/m²) nelle regioni spettrali, UVA, UVB, UVC e nella banda da 400 nm&#8230;1000 nm,in un segnale di tensione 0&#8230;10 V. Questa serie può essere installata sia all&#8217;esterno che all&#8217;interno.</p>
<p>Applicazioni principali in cui vengono impiegati i trasmettitori:</p>
<ul>
<li>Controllo dell’illuminamento (HD2021T ) in uffici, capannoni industriali, centri commerciali, teatri, aree museali, impianti sportivi, illuminazione stradale, gallerie ed impianti florovivaistici.</li>
<li>Controllo dell’irradiamento solare, nella banda spettrale 400nm ÷ 1100 nm (HD2021T1).</li>
<li>Controllo dell’irradiamento emesso dagli apparecchi abbronzanti nelle ragioni spettrali UVA (HD2021T.2), UVB (HD2021T.3), e controllo dell’efficienza dei filtri in apparecchi utilizzanti lampade ad alta pressione.</li>
<li>Controllo dell’efficienza delle lampade utilizzate negli impianti di depurazione, per il quale è necessario misurare l’irradiamento nella banda UVC (HD2021T.4).</li>
</ul>
<p>Modelli disponibili: <strong>HD2021T</strong> per illuminamento; <strong>HD2021T1</strong> per misurare l&#8217;irradiamento VIS-NIR; <strong>HD2021T2</strong> per misurare l&#8217;irradiamento UVA; <strong>HD2021T3</strong> per misurare l&#8217;irradiamento UVB; <strong>HD2021T4</strong> per misurare l&#8217;irradiamento UVC.</p>
<p>Amplificati con uscita 4&#8230;20mA o 0&#8230;.10 Vcc a seconda della versione scelta.</p>
<p>&nbsp;</p>
<p hidden="">HD2021T.AA, HD2021T.AV, HD2021T.BA, HD2021T.BV, HD2021T.CA, HD2021T.CV, HD2021T1.AA, HD2021T1.AV, HD2021T1.BA, HD2021T1.BV, HD2021T1.CA, HD2021T1.CV, HD2021T2.AA, HD2021T2.AV, HD2021T2.BA, HD2021T2.BV, HD2021T2.CA, HD2021T2.CV, HD2021T3.AA, HD2021T3.AV, HD2021T3.BA, HD2021T3.BV, HD2021T4.AA, HD2021T4.AV, HD2021T4.BA, HD2021T4.BV</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2021t-serie-trasmettitori-fotometrici-e-radiometrici/">HD2021T Serie &#8211; Trasmettitori Fotometrici e Radiometrici</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
