<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Stazioni Meteo e Strumenti meteorologici - Senseca Italy Srl</title>
	<atom:link href="https://environmental.senseca.com/it/misura/stazioni-meteo-it/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/it/misura/stazioni-meteo-it/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Tue, 20 Jan 2026 11:55:25 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.8</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>Stazioni Meteo e Strumenti meteorologici - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/misura/stazioni-meteo-it/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Serie RTD – Pluviometri a vaschetta basculante</title>
		<link>https://environmental.senseca.com/it/prodotto/serie-rtd-pluviometri-a-vaschetta-basculante/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Thu, 06 Nov 2025 11:59:52 +0000</pubDate>
				<guid isPermaLink="false">https://environmental.senseca.com/?post_type=product&#038;p=16434</guid>

					<description><![CDATA[<p>La soluzione precisa, robusta e conforme al WMO per il monitoraggio affidabile delle precipitazioni</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/serie-rtd-pluviometri-a-vaschetta-basculante/">Serie RTD – Pluviometri a vaschetta basculante</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p data-start="441" data-end="890">La <strong data-start="444" data-end="457">serie RTD</strong> rappresenta una nuova generazione di <strong data-start="495" data-end="533">pluviometri a vaschetta basculante</strong>, progettati in piena conformità alle raccomandazioni <strong data-start="587" data-end="600">WMO-No. 8</strong> (“Guide to Instruments and Methods of Observation”).<br data-start="653" data-end="656" />Realizzati interamente con <strong data-start="683" data-end="723">materiali resistenti alla corrosione</strong>, garantiscono <strong data-start="738" data-end="805">accuratezza a lungo termine, affidabilità e minima manutenzione</strong>, assicurando misure di <strong data-start="829" data-end="857">pioggia e precipitazioni</strong> precise in qualsiasi ambiente.</p>
<p data-start="892" data-end="1382">L’acqua piovana raccolta dal <strong data-start="921" data-end="942">cono in alluminio</strong> confluisce in una <strong data-start="961" data-end="992">vaschetta basculante tarata</strong>. Raggiunto il volume prefissato, la vaschetta si ribalta, scarica l’acqua e ritorna nella posizione iniziale, generando un <strong data-start="1116" data-end="1137">impulso elettrico</strong> facilmente acquisibile da <strong data-start="1164" data-end="1193">datalogger o contaimpulsi</strong>.<br data-start="1194" data-end="1197" />Disponibili con <strong data-start="1213" data-end="1259">area del collettore da 200 cm² o 400 cm²</strong>, i pluviometri RTD si adattano a diverse applicazioni e <strong>standard di installazione per reti meteorologiche e idrologiche.</strong></p>
<p data-start="1384" data-end="1516">Progettata per una <strong data-start="1403" data-end="1461">perfetta integrazione nei sistemi di acquisizione dati</strong>, la serie RTD offre diverse <strong data-start="1490" data-end="1513">tipologie di uscita</strong>:</p>
<ul>
<li data-start="1519" data-end="1556"><strong data-start="1519" data-end="1534">Contatto NC</strong> a potenziale libero</li>
<li data-start="1559" data-end="1614"><strong data-start="1559" data-end="1579">Uscite digitali:</strong> RS485, SDI-12, MOSFET Open Drain</li>
<li data-start="1617" data-end="1658"><strong data-start="1617" data-end="1639">Uscite analogiche:</strong> 4…20 mA o 0…10 V</li>
</ul>
<p data-start="1660" data-end="2054">Le <strong data-start="1663" data-end="1686">versioni riscaldate</strong> si attivano automaticamente intorno a <strong data-start="1725" data-end="1734">+4 °C</strong>, con <strong data-start="1740" data-end="1757">controllo PID</strong> (modelli digitali/analogici) o <strong data-start="1789" data-end="1799">ON/OFF</strong> (modelli a contatto), garantendo misure affidabili anche in presenza di neve o ghiaccio.<br data-start="1888" data-end="1891" />Un <strong data-start="1894" data-end="1926">filtro d’ingresso removibile</strong> e un <strong data-start="1932" data-end="1982">cono raccoglitore con trattamento antiaderente</strong> semplificano la manutenzione e assicurano un flusso d’acqua regolare.</p>
<p data-start="2056" data-end="2240">Ideale per applicazioni di <strong data-start="2083" data-end="2136">meteorologia, idrologia e monitoraggio ambientale</strong>, la serie RTD offre <strong data-start="2157" data-end="2202">dati di precipitazione precisi e costanti</strong> anche nelle condizioni più difficili.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/serie-rtd-pluviometri-a-vaschetta-basculante/">Serie RTD – Pluviometri a vaschetta basculante</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DataRain-4000 – Sensore elettronico di precipitazione a pesata</title>
		<link>https://environmental.senseca.com/it/prodotto/datarain-4000-pluviometro-a-pesata/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 30 Dec 2025 09:11:48 +0000</pubDate>
				<guid isPermaLink="false">https://environmental.senseca.com/product/datarain-4000-pluviometro-a-pesata/</guid>

					<description><![CDATA[<p>Misura delle precipitazioni ad alta accuratezza, <strong>conforme alle raccomandazioni WMO</strong>, per il monitoraggio professionale meteorologico e ambientale.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/datarain-4000-pluviometro-a-pesata/">DataRain-4000 – Sensore elettronico di precipitazione a pesata</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><a href="https://www.geonica.com/en/datarain-4000.php">Documentazione completa DATARAIN-4000 &#8211; clicca qui.</a></strong></p>
<p><strong data-start="135" data-end="152">DataRain-4000</strong> è un <strong data-start="158" data-end="208">pluviometro professionale a pesata elettronica</strong>, progettato in linea con le <strong data-start="237" data-end="260">raccomandazioni WMO</strong> per il monitoraggio delle precipitazioni ad alta accuratezza. Combina una <strong data-start="335" data-end="357">cella di carico C3</strong> ad alta precisione con un sistema di <strong data-start="395" data-end="421">svuotamento automatico</strong>, offrendo una capacità cumulata praticamente illimitata con manutenzione minima, anche durante eventi di pioggia estrema fino a <strong data-start="550" data-end="563">2000 mm/h</strong>.</p>
<p>Grazie al principio di misura <strong data-start="596" data-end="608">a pesata</strong>, il sensore garantisce una <strong data-start="636" data-end="663">calibrazione permanente</strong>, mantenendo una risoluzione fino a <strong data-start="699" data-end="711">0,001 mm</strong> e un’accuratezza dello <strong data-start="735" data-end="744">0,02%</strong> su tutto il range. Sono disponibili due versioni con area di raccolta <strong data-start="815" data-end="836">200 cm² o 400 cm²</strong>, con <strong data-start="842" data-end="865">consumo ultra-basso</strong> e, opzionalmente, un <strong data-start="887" data-end="917">riscaldamento intelligente</strong> a basso consumo controllato da una sonda di temperatura interna, per un funzionamento affidabile in tutte le condizioni meteo. Le diverse uscite e i protocolli disponibili rendono DataRain-4000 facilmente integrabile in nuove installazioni o reti di monitoraggio esistenti.</p>
<h3>Vantaggi principali</h3>
<ul>
<li data-start="1217" data-end="1325">
<p data-start="1219" data-end="1325">Pluviometro a pesata elettronica <strong data-start="1252" data-end="1268">conforme WMO</strong> per il monitoraggio professionale delle precipitazioni</p>
</li>
<li data-start="1326" data-end="1402">
<p data-start="1328" data-end="1402"><strong data-start="1328" data-end="1365">Sistema di svuotamento automatico</strong> per una misura cumulata illimitata</p>
</li>
<li data-start="1403" data-end="1477">
<p data-start="1405" data-end="1477">Range di intensità <strong data-start="1424" data-end="1439">0–2000 mm/h</strong> con risoluzione fino a <strong data-start="1463" data-end="1475">0,001 mm</strong></p>
</li>
<li data-start="1478" data-end="1556">
<p data-start="1480" data-end="1556"><strong data-start="1480" data-end="1501">Accuratezza 0,02%</strong> (cella di carico C3) con <strong data-start="1527" data-end="1554">calibrazione permanente</strong></p>
</li>
<li data-start="1557" data-end="1612">
<p data-start="1559" data-end="1612">Versioni con area di raccolta <strong data-start="1589" data-end="1610">200 cm² o 400 cm²</strong></p>
</li>
<li data-start="1613" data-end="1719">
<p data-start="1615" data-end="1719"><strong data-start="1615" data-end="1638">Consumo ultra-basso</strong> con <strong data-start="1643" data-end="1673">riscaldamento intelligente</strong> opzionale per precipitazioni fredde o miste</p>
</li>
<li data-start="1720" data-end="1873">
<p data-start="1722" data-end="1873">Integrazione semplice tramite <strong data-start="1752" data-end="1772">uscita a impulsi</strong>, <strong data-start="1774" data-end="1812">RS-232/RS-485 (Modbus, ASCII/NMEA)</strong> o <strong data-start="1815" data-end="1825">SDI-12</strong>, più <strong data-start="1831" data-end="1838">USB</strong> per configurazione e aggiornamenti</p>
</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/datarain-4000-pluviometro-a-pesata/">DataRain-4000 – Sensore elettronico di precipitazione a pesata</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CPM12AA4&#8230; Serie &#8211; Cavo 4 poli connettore M12</title>
		<link>https://environmental.senseca.com/it/prodotto/cpm12aa4-serie-cavo-4-poli-connettore-m12/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:21:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/cpm12aa4-serie-cavo-4-poli-connettore-m12/</guid>

					<description><![CDATA[<p>Cavo a 4 poli. Connettore M12 4 poli da un lato, fili aperti dall’altro</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa4-serie-cavo-4-poli-connettore-m12/">CPM12AA4&#8230; Serie &#8211; Cavo 4 poli connettore M12</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cavo a 4 poli. Connettore M12 4 poli da un lato, fili aperti dall’altro.</p>
<p>Lunghezze disponibili: 5 m (CPM12AA4.5) e 10 m ( CPM12AA4.10).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa4-serie-cavo-4-poli-connettore-m12/">CPM12AA4&#8230; Serie &#8211; Cavo 4 poli connettore M12</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CPM12AA8&#8230; Serie &#8211; Cavo 8 poli</title>
		<link>https://environmental.senseca.com/it/prodotto/cpm12aa8-serie-8-pole-m12-connector-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:21:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/cpm12aa8-serie-cavo-8-poli-connettore-m12/</guid>

					<description><![CDATA[<p>Cavo a 8 poli. Connettore M12 8 poli da un lato, fili aperti dall’altro</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa8-serie-8-pole-m12-connector-2/">CPM12AA8&#8230; Serie &#8211; Cavo 8 poli</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Cavo a 8 poli. Connettore M12 8 poli da un lato, fili aperti dall’altro (non adatto per sensori con uscita RS485 e SDI-12).</p>
<p>Lunghezze disponibili :  5 m ( CPM12AA8.5 ) e 10 m ( CPM12AA8.10).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/cpm12aa8-serie-8-pole-m12-connector-2/">CPM12AA8&#8230; Serie &#8211; Cavo 8 poli</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD9008.26/14 &#8211; Adattatore</title>
		<link>https://environmental.senseca.com/it/prodotto/hd9008-26-14-adattatore/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd9008-26-14-adattatore/</guid>

					<description><![CDATA[<p>Riduzione per sonde Ø 14 mm per le protezioni dalle radiazioni solari HD9007A-1 e HD9007A-2.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd9008-26-14-adattatore/">HD9008.26/14 &#8211; Adattatore</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Si prega di notare che questo codice è fuori produzione. Si prega di fare riferimento a HD9007T26.2</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd9008-26-14-adattatore/">HD9008.26/14 &#8211; Adattatore</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2013 &#8211; Pluviometro a Vaschetta Basculante</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2013-pluviometro-a-vaschetta-basculante/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2013-pluviometro-a-vaschetta-basculante/</guid>

					<description><![CDATA[<p>Pluviometro a vaschetta basculante, area 400 cm<sup>2</sup>, Temperatura di funzionamento -20 (versione riscaldata)... +70°C.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2013-pluviometro-a-vaschetta-basculante/">HD2013 &#8211; Pluviometro a Vaschetta Basculante</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>HD2013</strong> è un pluviometro a vaschetta basculante affidabile e robusto, costruito interamente con materiali resistenti alla corrosione per garantire affidabilità, precisione e durata nel tempo. A seconda dell&#8217;ambiente in cui è collocato, è possibile scegliere tra una versione <strong>riscaldata o non riscaldata</strong> (HD2013R).</p>
<p>La misura della quantità di pioggia si basa sul conteggio del numero di svuotamenti della vaschetta: i contatti reed, normalmente chiusi, si aprono al momento della rotazione tra una sezione e l’altra della vaschetta. Questo significa che il principio a vaschetta basculante ha un enorme vantaggio: non necessita di alimentazione elettrica per funzionare. L&#8217;alimentazione è necessaria solo quando le circostanze richiedono un riscaldamento a causa delle basse temperature ambientali.</p>
<p>Il numero degli impulsi può essere rilevato ed acquisito da un datalogger come  <a href="https://environmental.senseca.com/product/hd2013-db-visualizzatore-datalogger-di-pioggia/?lang=it">HD2013-DB</a>. Ma è anche possibile comunicare direttamente i risultati attraverso uno dei nostri datalogger della <a href="https://environmental.senseca.com/product/hd33mt-4-datalogger-per-stazioni-meteo-4g/?lang=it">serie HD33.</a> Il modem 4G/3G/GPRS integrato rende semplice l&#8217;upload dei dati direttamente su una delle nostre applicazioni cloud o in un server proprietario.</p>
<p>HD2013 è disponibile anche con uscita analogica opzionale a scelta tra 4&#8230;20 mA o 0&#8230;10 Vdc (da specificare al momento dell&#8217;ordine) o con uscita digitale SDI-12 opzionale. Al momento dell&#8217;ordine, il pluviometro viene completamente predisposto per l&#8217;uso.</p>
<p>Facile da installare, piedini regolabili e dispositivo di livellamento integrato. Disponibili e ordinabili a parte, dissuasore per volatili e accessori per l&#8217;installazione su palo.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2013-pluviometro-a-vaschetta-basculante/">HD2013 &#8211; Pluviometro a Vaschetta Basculante</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2003.77C &#8211; Bussole a Croce</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2003-77c-bussole-a-croce/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:21:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2003-77c-bussole-a-croce/</guid>

					<description><![CDATA[<p>2 bussole a croce per tubo Ø40 mm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2003-77c-bussole-a-croce/">HD2003.77C &#8211; Bussole a Croce</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Si prega di notare che questo articolo è fuori produzione.</p>
<p>Per ulteriori informazioni, si prega di contattare Senseca.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2003-77c-bussole-a-croce/">HD2003.77C &#8211; Bussole a Croce</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2003.1 &#8211; Anemometro Ultrasonico Triassiale</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2003-1-anemometro-ultrasonico-triassiale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:21:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2003-1-anemometro-ultrasonico-triassiale/</guid>

					<description><![CDATA[<p>Anemometro a ultrasuoni statico triassiale per la misurazione della velocità e della direzione del vento.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2003-1-anemometro-ultrasonico-triassiale/">HD2003.1 &#8211; Anemometro Ultrasonico Triassiale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Si prega di notare che questo prodotto così come il suo corrispondente con opzione riscaldamento (HD2003.1<strong>R</strong>) <strong>sono fuori produzione</strong>.</p>
<p>Manuale e datasheet sono ancora disponibili alla sezione download.</p>
<p>La versione con misurazione aggiuntiva di temperatura, umidità dell&#8217;aria e pressione barometrica, è ancora disponibile. Si faccia riferimento al codice prodotto <strong><a href="https://environmental.senseca.com/product/hd2003-anemometro-ultrasonico-triassiale/?lang=it">HD2003</a>.</strong></p>
<p>Per tutte le informazioni relative al nostro nuovo anemometro triassiale, si veda la <a href="https://environmental.senseca.com/it/prodotto/aeolus-3-anemometro-ultrasonico-a-3-assi/"><strong>nuova serie AEOLUS-3</strong></a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2003-1-anemometro-ultrasonico-triassiale/">HD2003.1 &#8211; Anemometro Ultrasonico Triassiale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2003 &#8211; Anemometro Ultrasonico Triassiale Multiparametro</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2003-anemometro-ultrasonico-triassiale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2003-anemometro-ultrasonico-triassiale/</guid>

					<description><![CDATA[<p>Anemometro a ultrasuoni statico a tre assi per misurare la velocità e la direzione del vento, la temperatura dell'aria, l'umidità relativa e la pressione barometrica.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2003-anemometro-ultrasonico-triassiale/">HD2003 &#8211; Anemometro Ultrasonico Triassiale Multiparametro</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD2003 è un anemometro ad ultrasuoni statico a 3 assi per la misura della <strong>velocità e direzione del vento, temperatura dell’aria, umidità relativa e pressione barometrica. Componenti cartesiane U-V-W della velocità del vento, Wind Gust, velocità del suono, temperatura sonica.</strong></p>
<p>Le principali caratteristiche dello strumento sono:</p>
<ul>
<li>5 uscite analogiche in corrente e tensione, con diversi range di misura.</li>
<li>Interfacce digitali di comunicazione: Seriale RS232, MultiDrop RS485.</li>
<li>Stringhe digitali dei dati di uscita con frequenza di emissione impostabile.</li>
<li>Periodi di media impostabili da 1÷60 sec oppure da 1÷60 min. per tutte le grandezze di uscita.</li>
<li>Algoritmi di elaborazione e validazione dei segnali grezzi di misura, per fornire la misura della grandezza anemometrica con precisione ±1%.</li>
<li>Modalità di funzionamento in alta frequenza Digitale con output dati seriali a 50Hz.</li>
<li>Autodiagnosi con checking e report degli errori.</li>
<li>Affidabilità e precisione in tutto il campo di misura, senza necessità di ulteriori calibrazioni.</li>
<li>Software operativo demo flessibile, di semplice impiego, adattabile alle esigenze dell&#8217;utente tramite interfaccia computer.</li>
<li>Bussola con sensore magnetoresistivo per l&#8217;allineamento automatico al Nord Magnetico.</li>
<li>Nessuna parte in movimento, con costi di manutenzione e servizio ridotti.</li>
<li>Costruzione robusta, adatta ad operare con continuità in severe condizioni ambientali.</li>
<li>Basso consumo elettrico.</li>
</ul>
<p>Disponibile anche con opzione riscaldamento (HD2003<strong>R</strong>): dispositivo integrato nei sensori sonici, per evitare la formazione di ghiaccio, ed operare correttamente anche in condizioni di nevischio o neve.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2003-anemometro-ultrasonico-triassiale/">HD2003 &#8211; Anemometro Ultrasonico Triassiale Multiparametro</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD9817T serie &#8211; Trasmettitori Umidità Relativa e Temperatura</title>
		<link>https://environmental.senseca.com/it/prodotto/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/</guid>

					<description><![CDATA[<p>Trasmettitori meteorologici di umidità relativa o temperatura con uscita digitale</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/">HD9817T serie &#8211; Trasmettitori Umidità Relativa e Temperatura</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Doppio trasmettitore di umidità relativa e temperatura per applicazioni nei campi HVAC, monitoraggio ambientale, stoccaggio di prodotti farmaceutici, trasporto di prodotti alimentari, automazione serre, ecc. Sviluppato in un contenitore AISI 304 con grado di protezione IP65, è adatto per essere impiegato anche in ambienti severi; inoltre le dimensioni estremamente compatte (∅ 14 x 145 mm) e la varietà di uscite disponibili (analogiche 0&#8230;1V, digitali RS232C o RS485 MODBUS-RTU) lo rendono ideale per essere integrato in gran numero di applicazioni OEM. È fornito con software HD9817TC software per la lettura delle misure da PC e la calibrazione del sensore di umidità relativa.</p>
<p>Sono disponibili le seguenti versioni:</p>
<p><strong>HD9817T1R</strong>: Doppio trasmettitore temperatura e umidità relativa. Temperatura sensore Pt100 1/3 DIN. Campo di misura in umidità relativa: 0&#8230;100% UR, in temperatura: -40&#8230;+60 °C. Doppio segnale di uscita 0&#8230;1 Vdc. Alimentazione 5&#8230;30 Vdc. Contenitore in AISI 304, dimensioni ∅ 14 mm, L = 138 mm. Configurazione standard 0&#8230;100% UR = 0&#8230;1 Vdc, -40&#8230;+60 °C = 0&#8230;1 Vdc. Cavo 7 fili più calza L = 1,5 m.</p>
<p><strong>HD9817T2R</strong>: Doppio trasmettitore temperatura e umidità relativa. Temperatura sensore Pt100 1/3 DIN. Campo di misura in umidità relativa: 0&#8230;100 %UR, in temperatura: -40&#8230;+60 °C. Uscita RS232C. Alimentazione non isolata prelevata dall’uscita RS232C del PC. Contenitore in AISI 304, dimensioni ∅ 14 mm, L = 138 mm. Configurazione standard 0&#8230;100 %UR in umidità relativa e -40&#8230;+60 °C in temperatura. Cavo di uscita con connettore DB9 femmina, L = 2 m. Baud rate 2400.</p>
<p><strong>HD9817TVS</strong>:Doppio trasmettitore di umidità e temperatura, sensore Pt100. Uscite analogiche 0&#8230;1 Vdc e uscita RS485 MODBUS-RTU. Campo di misura in temperatura -40&#8230;+60 °C. Alimentazione 5&#8230;30 Vdc. Contenitore AISI 304. Grado di protezione della sonda IP 65. Dimensioni ∅14 x 155 mm. Uscita con connettore M12 a 8 poli maschio. Fornito con cavo CP9817.3, lunghezza 3 m.</p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/">HD9817T serie &#8211; Trasmettitori Umidità Relativa e Temperatura</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
