<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HD2010UC.kit1 Archives - Senseca Italy Srl</title>
	<atom:link href="https://environmental.senseca.com/it/tag-prodotto/hd2010uc-kit1-it/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/it/tag-prodotto/hd2010uc-kit1-it/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Wed, 29 Jun 2022 11:04:07 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>HD2010UC.kit1 Archives - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/tag-prodotto/hd2010uc-kit1-it/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HD2010UC.kit2 – Fonometro Integratore Classe 2</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2010uc-kit2-fonometro-integratore-classe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 03 Oct 2018 16:04:19 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2010uc-kit2-class-2-integrating-sound-level-meter/</guid>

					<description><![CDATA[<p>Fonometro integratore di classe 2 secondo norma IEC 61672.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2010uc-kit2-fonometro-integratore-classe-2/">HD2010UC.kit2 – Fonometro Integratore Classe 2</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD2010UC è un <strong>fonometro integratore portatile</strong> <strong>di classe 2</strong> in grado di effettuare analisi statistiche. Lo strumento è stato progettato coniugando economicità e semplicità di uso. Attenzione è stata dedicata alla possibilità di aggiornare lo strumento ed è possibile integrare, in qualunque momento, il fonometro con l’opzione “Data Logger Avanzato” in grado di estenderne le applicazioni.</p>
<p>Il firmware è aggiornabile direttamente dall’utente utilizzando il programma NoiseStudio fornito in dotazione.</p>
<p>HD2010UC soddisfa le specifiche delle norme IEC 61672-1 del 2002 e IEC 61672-1 Ed. 2.0 del 2013 e delle norme IEC 60651 ed IEC 60804 con tolleranze di classe 2 o di classe 1.</p>
<p>Il fonometro è adatto alle seguenti applicazioni:</p>
<ul>
<li>valutazioni del <strong>livello di rumore ambientale</strong>,</li>
<li>misure in <strong>ambiente di lavoro</strong>,</li>
<li>selezione dei <strong>dispositivi di protezione</strong> individuale (metodi SNR ed HML),</li>
<li>controllo <strong>qualità della produzione</strong>,</li>
<li>misura del <strong>rumore di macchine</strong></li>
</ul>
<p>Con l’attivazione dell’opzione “Data Logger Avanzato” il fonometro svolge inoltre le seguenti funzioni:</p>
<ul>
<li>monitoraggio del rumore,</li>
<li>identificazione ed analisi di eventi sonori,</li>
<li>analisi statistica completa con calcolo dei livelli percentili da L<sub>1</sub> ad L<sub>99</sub>.</li>
</ul>
<p>Il kit comprende: fonometro HD2010UC classe 2, microfono a condensatore pre-polarizzato da 1/2&#8221; UC52, schermo antivento, preamplificatore, cavo USB o RS232, valigetta, dichiarazione di conformità, versione base software Noise Studio.</p>
<p>Per Classe 1 si veda codice <a href="https://environmental.senseca.com/product/hd2010uc-kit1-fonometro-integratore-classe-1/?lang=it">HD2010UC.kit1</a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2010uc-kit2-fonometro-integratore-classe-2/">HD2010UC.kit2 – Fonometro Integratore Classe 2</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2010UC/A.Kit1 – Fonometro Integratore Analizzatore di Spettro Classe 1</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2010uc-a-kit1-fonometro-integratore-analizzatore-di-spettro-classe-1/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 03 Oct 2018 16:25:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2010uc-a-kit1-class-1-integrating-sound-level-meter-and-analyzer/</guid>

					<description><![CDATA[<p>Fonometro integratore ed analizzatore di spettro con funzioni di data logging, Classe 1 della norma IEC 61672 e IEC 61260.</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2010uc-a-kit1-fonometro-integratore-analizzatore-di-spettro-classe-1/">HD2010UC/A.Kit1 – Fonometro Integratore Analizzatore di Spettro Classe 1</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>HD2010UC/A</strong> è un fonometro integratore portatile in grado di effettuare <strong>analisi spettrali e statistiche.</strong></p>
<p>Lo strumento è stato progettato coniugando la massima flessibilità di utilizzo con la economicità e semplicità di uso. Attenzione è stata dedicata alla possibilità di adattare lo strumento all’evoluzione della normativa in materia di rumore ed alla necessità di soddisfare le esigenze odierne e future dei suoi utilizzatori. E’ possibile integrare in qualunque momento il fonometro con opzioni in grado di estenderne le applicazioni; il firmware è aggiornabile direttamente dall’utente utilizzando il programma NoiseStudio fornito in dotazione.</p>
<p>HD2010UC/A soddisfa le specifiche della norma IEC 61672-1 del 2002 e IEC 61672-1 Ed. 2.0 del 2013 e delle norme IEC 60651 ed IEC 60804 con tolleranze di classe 2 o di classe 1. I filtri a banda percentuale costante sono conformi alle specifiche di classe 1 della norma IEC 61260.</p>
<p>HD2010UC/A è adatto alle seguenti applicazioni:</p>
<ul>
<li>valutazioni e monitoraggio del <strong>rumore ambientale</strong>,</li>
<li><strong>analisi spettrali per bande d’ottava</strong> da 31.5Hz ad 8kHz,</li>
<li>opzionalmente <strong>analisi spettrali per bande di terzo d’ottava</strong> da 25Hz a 12.5kHz,</li>
<li>analisi statistica con <strong>calcolo dei livelli percentili</strong> da L<sub>1</sub> ad L<sub>99</sub>,</li>
<li>identificazione ed analisi di <strong>eventi sonori,</strong></li>
<li>misure in <strong>ambiente di lavoro</strong>,</li>
<li>selezione dei <strong>dispositivi di protezione</strong> individuale (metodi SNR, HML ed OBM),</li>
<li><strong>insonorizzazioni e bonifiche</strong> acustiche,</li>
<li><strong>controllo qualità</strong> della produzione,</li>
<li>misura del <strong>rumore di macchine</strong>,</li>
<li>opzionalmente <strong>acustica architettonica</strong>.</li>
</ul>
<p>Il kit include: fonometro HD2010UC/A Classe 1, microfono a condensatore prepolarizzato da 1/2&#8221; UC52/1, schermo antivento, preamplificatore, cavo USB o RS232, valigetta, dichiarazione di conformità, versione base software Noise Studio.</p>
<p>Per Classe 2 si veda <a href="https://environmental.senseca.com/it/prodotto/hd2010uc-a-kit2-fonometro-integratore-analizzatore-di-spettro-classe-2/">HD2010UC/A.kit2</a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2010uc-a-kit1-fonometro-integratore-analizzatore-di-spettro-classe-1/">HD2010UC/A.Kit1 – Fonometro Integratore Analizzatore di Spettro Classe 1</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
