	<lastBuildDate>Mon, 13 Nov 2023 12:15:30 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>ISO7726 Archives - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/tag-prodotto/iso7726-it/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HD32.2 &#8211; Datalogger per Analisi WBGT</title>
		<link>https://environmental.senseca.com/it/prodotto/hd32-2-datalogger-per-analisi-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-2-datalogger-per-analisi-wbgt/</guid>

					<description><![CDATA[<p>Thermal microclimate per la misura del WBGT Index in ambienti caldi. Portatile.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-2-datalogger-per-analisi-wbgt/">HD32.2 &#8211; Datalogger per Analisi WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD32.2 è stato studiato per l’analisi dell’indice <strong>WBGT (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globo-termometro)</strong> in ambienti caldi in conformità alle norme ISO 7726 e ISO 7243.</p>
<p>Lo strumento è dotato di tre ingressi per sonde con modulo SICRAM: le sonde dispongono di un circuito elettronico che dialoga con lo strumento, nella loro memoria permanente sono conservati i dati di taratura del sensore.<br />
Tutte le sonde SICRAM possono essere inserite in uno qualunque degli ingressi: vengono riconosciute automaticamente all’accensione dello strumento.</p>
<p>Le caratteristiche principali dello strumento sono:</p>
<ul>
<li><strong>Logging:</strong> acquisizione dei dati e memorizzazione all’interno dello strumento. Capacità di memoria: 64 sessioni di logging distinte, con la possibilità di impostare l’intervallo di acquisizione dei campioni. Si può impostare la durata della memorizzazione e, con la funzione auto-start, è possibile impostare la data e l’ora di inizio e di fine di memorizzazione dei dati.</li>
<li>L’unità di misura delle grandezze di temperatura visualizzate: °C, °F, °K.</li>
<li>La data e l’ora del sistema.</li>
<li>La visualizzazione dei parametri statistici massimo, minimo, media e la loro cancellazione.</li>
<li>La velocità di trasferimento dei dati tramite la porta seriale RS232.</li>
</ul>
<p>Lo strumento HD32.2 è in grado di rilevare contemporaneamente le seguenti grandezze:</p>
<ul>
<li><strong>Temperatura di globotermometro Tg.</strong></li>
<li><strong>Temperatura di bulbo umido a ventilazione naturale Tn.</strong></li>
<li><strong>Temperatura ambiente T.</strong></li>
</ul>
<p>Sulla base delle grandezze rilevate HD32.2 è in grado di calcolare:</p>
<ul>
<li><strong>Indice WBGT(in)</strong> (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globotermometro) in assenza di irraggiamento solare.</li>
<li><strong>Indice WBGT(out)</strong> (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globotermometro) in presenza di irraggiamento solare.</li>
</ul>
<p>Sonde necessarie per la misura del WBGT:</p>
<ul>
<li>Sonda di temperatura di bulbo secco TP3207.2.</li>
<li>Sonda di temperatura globotermometro TP3276.2.</li>
<li>Sonda di temperatura di bulbo umido a ventilazione naturale HP3201.2.</li>
</ul>
<p>HD32.2 è la versione portatile, utilizzata per lo più in combinazione con un supporto da tavolo (treppiede piccolo). Per misurazioni di lunga durata si consiglia la versione con treppiede stabile HD32.3A.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-2-datalogger-per-analisi-wbgt/">HD32.2 &#8211; Datalogger per Analisi WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3 &#8211; Datalogger per Misure WBGT, PMW, PPD</title>
		<link>https://environmental.senseca.com/it/prodotto/hd32-3-datalogger-per-misure-wbgt-pmw-ppd/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3-wbgt-pmw-ppd-measurement/</guid>

					<description><![CDATA[<p>Thermal microclimate per misurare l'indice WBGT, indice PMV (voto medio previsto) e PPD (percentuale prevista di insoddisfatti). 3 ingressi per sonde con modulo SICRAM, display grafico.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-3-datalogger-per-misure-wbgt-pmw-ppd/">HD32.3 &#8211; Datalogger per Misure WBGT, PMW, PPD</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate per la misura del WBGT Index, PMV Index (voto medio previsto) e PPD percentuale prevista di insoddisfatti. Ingresso 3 canali per sonde con modulo SICRAM, display grafico.</p>
<p>Include software DeltaLog 10 (con analisi indici WBGT, PMV e PPD) scaricabile dal sito web Senseca.</p>
<p>Il kit è composto da strumento HD32.3, 4 batterie AA da 1,5 V, manuale d’istruzioni.</p>
<p>Le sonde e i cavi vanno richiesti a parte.</p>
<p>Le sonde necessarie per la misura del WBGT sono:</p>
<ul>
<li>Sonda di temperatura di bulbo secco TP3207.2.</li>
<li>Sonda di temperatura globotermometro TP3276.2.</li>
<li>Sonda di temperatura di bulbo umido a ventilazione naturale HP3201.2.</li>
</ul>
<p>Le sonde necessarie per la misura del PMV e PPD sono:</p>
<ul>
<li>Sonda combinata temperatura e umidità relativa HP3217.2.</li>
<li>Sonda a filo caldo omnidirezionale AP3203.2.</li>
<li>Sonda di temperatura globotermometro TP3276.2.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-3-datalogger-per-misure-wbgt-pmw-ppd/">HD32.3 &#8211; Datalogger per Misure WBGT, PMW, PPD</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.2A &#8211; Datalogger per Analisi WBGT</title>
		<link>https://environmental.senseca.com/it/prodotto/hd32-2a-datalogger-per-analisi-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-2a-datalogger-per-analisi-wbgt/</guid>

					<description><![CDATA[<p>Thermal microclimate per la misura del WBGT Index in ambienti caldi.</p>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-2a-datalogger-per-analisi-wbgt/">HD32.2A &#8211; Datalogger per Analisi WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD32.2A è stato studiato per l’analisi dell’indice<strong> WBGT (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globo-termometro)</strong> in ambienti caldi in conformità alle norme ISO 7726 e ISO 7243.</p>
<p>Installato su treppiede VTRAP32.2A.3A, lo strumento permette misurazioni per lunghi periodi. E&#8217; dotato di tre ingressi per sonde con cavo da fissare all&#8217;apposito supporto HD32.2.7.1. Le sonde sono dotate di modulo SICRAM: dispongono di un circuito elettronico che dialoga con lo strumento, nella loro memoria permanente sono conservati i dati di taratura del sensore. Tutte le sonde SICRAM possono essere inserite in uno qualunque degli ingressi: vengono riconosciute automaticamente all’accensione dello strumento.</p>
<p>Le caratteristiche principali dello strumento sono:</p>
<ul>
<li>Logging: acquisizione dei dati e memorizzazione all’interno dello strumento. Capacità di memoria: 64 sessioni di logging distinte, con la possibilità di impostare l’intervallo di acquisizione dei campioni. Si può impostare la durata della memorizzazione e, con la funzione auto-start, è possibile impostare la data e l’ora di inizio e di fine di memorizzazione dei dati.</li>
<li>L’unità di misura delle grandezze di temperatura visualizzate: °C, °F, °K.</li>
<li>La data e l’ora del sistema.</li>
<li>La visualizzazione dei parametri statistici massimo, minimo, media e la loro cancellazione.</li>
<li>La velocità di trasferimento dei dati tramite la porta seriale RS232.</li>
</ul>
<p>Lo strumento HD32.2A è in grado di rilevare contemporaneamente le seguenti grandezze:</p>
<ul>
<li><strong>Temperatura di globotermometro Tg.</strong></li>
<li><strong>Temperatura di bulbo umido a ventilazione naturale Tn.</strong></li>
<li><strong>Temperatura ambiente T.</strong></li>
</ul>
<p>Sulla base delle grandezze rilevate HD32.2A è in grado di calcolare:</p>
<ul>
<li><strong>Indice WBGT(in)</strong> (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globotermometro) in assenza di irraggiamento solare.</li>
<li><strong>Indice WBGT(out)</strong> (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globotermometro) in presenza di irraggiamento solare.</li>
</ul>
<p>Sonde necessarie per la misura del WBGT:</p>
<ul>
<li>Sonda di temperatura di bulbo secco TP3207.</li>
<li>Sonda di temperatura globotermometro TP3275.</li>
<li>Sonda di temperatura di bulbo umido a ventilazione naturale HP3201 o TP3204S.</li>
</ul>
<p>Si veda anche versione portatile HD32.2.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-2a-datalogger-per-analisi-wbgt/">HD32.2A &#8211; Datalogger per Analisi WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		