<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>radiometric probe Archives - Senseca Italy Srl</title>
	<atom:link href="https://environmental.senseca.com/it/tag-prodotto/radiometric-probe-it/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/it/tag-prodotto/radiometric-probe-it/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Mon, 22 Mar 2021 11:38:06 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>radiometric probe Archives - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/tag-prodotto/radiometric-probe-it/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LP471UVBC &#8211; Sonda Radiometrica UV-BC</title>
		<link>https://environmental.senseca.com/it/prodotto/lp471uvbc-sonda-radiometrica-uv-bc/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Fri, 05 Mar 2021 11:24:48 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uvbc-sonda-radiometrica-uv-bc/</guid>

					<description><![CDATA[<p>Sonda radiometrica per la misura dell’irradiamento nel campo spettrale UV-BC 210 nm…355 nm, picco a 265 nm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lp471uvbc-sonda-radiometrica-uv-bc/">LP471UVBC &#8211; Sonda Radiometrica UV-BC</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>LP471UVBC è una <strong>sonda radiometrica per la misurazione dell&#8217;irradiamento (W/m²) nell&#8217;campo spettrale 210&#8230;355 nm</strong> con picco a 265 nm. È dotata di un connettore con modulo SICRAM e di un cavo di 2 m</p>
<p>La sonda è composta da un fotodiodo con un filtro appropriato ed è dotata di un diffusore per una corretta misurazione secondo la legge del coseno. Viene tipicamente utilizzata nella <strong>verifica delle lampade germicide utilizzate negli impianti di sterilizzazione</strong> che lavorano con LED come sorgenti di luce UV.</p>
<p>La sonda è disponibile anche già combinata in kit pronti all&#8217;uso. A seconda delle vostre esigenze, potete scegliere una versione base composta dalla sonda e dal nostro luxmetro HD2302.0 per misurare e leggere semplicemente i valori (UVBC-CK02-ACC). Per una versione più avanzata con funzione di data logging, la sonda è abbinata al nostro datalogger luxmetro portatile HD2102.2 (UVBC-CK01-ACC).</p>
<p>Per entrambe le soluzioni, la correttezza delle vostre misure è assicurata anche dal certificato di Taratura ISO 17025 rilasciato nel nostro laboratorio di foto-radiometria accreditato.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lp471uvbc-sonda-radiometrica-uv-bc/">LP471UVBC &#8211; Sonda Radiometrica UV-BC</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471BLUE &#8211; Sonda Irradiamento Efficace Luce Blu</title>
		<link>https://environmental.senseca.com/it/prodotto/lp471blue-sonda-irradiamento-efficace-luce-blu/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 11 Sep 2018 09:48:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471blue-effective-irradiance-radiometric-probe/</guid>

					<description><![CDATA[<p>Sonda radiometrica per la misura dell’ irradiamento efficace nella banda spettrale della luce blu.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lp471blue-sonda-irradiamento-efficace-luce-blu/">LP471BLUE &#8211; Sonda Irradiamento Efficace Luce Blu</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: left;">La sonda radiometrica LP471BLUE misura l’<strong>irradiamento efficace</strong> (W/m²) nella banda spettrale della <strong>luce Blu.</strong></p>
<p style="text-align: left;">La sonda è composta da un fotodiodo più un opportuno filtro ed è provvista di diffusore per la corretta misura secondo la legge del coseno.</p>
<p style="text-align: left;">La curva di risposta spettrale della sonda permette di misurare l’irradiamento efficace per danno da luce blu (curva B(λ) secondo gli standard ACGIH/ICNIRP) nel campo spettrale che va da <strong>380 nm a 550 nm. </strong></p>
<p style="text-align: left;">Le radiazioni ottiche in questa porzione di spettro possono produrre danni fotochimici alla retina. Altro ambito di utilizzo della sonda è il monitoraggio dell’irradiamento da luce blu utilizzato nelle <strong>terapie dell’ittero neonatale</strong>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/lp471blue-sonda-irradiamento-efficace-luce-blu/">LP471BLUE &#8211; Sonda Irradiamento Efficace Luce Blu</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>