<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>temperature and humidity transmitters Archives - Senseca Italy Srl</title>
	<atom:link href="https://environmental.senseca.com/it/tag-prodotto/temperature-and-humidity-transmitters-it/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/it/tag-prodotto/temperature-and-humidity-transmitters-it/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Tue, 15 Jul 2025 15:41:18 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>temperature and humidity transmitters Archives - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/tag-prodotto/temperature-and-humidity-transmitters-it/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HD9817T serie &#8211; Trasmettitori Umidità Relativa e Temperatura</title>
		<link>https://environmental.senseca.com/it/prodotto/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/</guid>

					<description><![CDATA[<p>Trasmettitori meteorologici di umidità relativa o temperatura con uscita digitale</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/">HD9817T serie &#8211; Trasmettitori Umidità Relativa e Temperatura</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Doppio trasmettitore di umidità relativa e temperatura per applicazioni nei campi HVAC, monitoraggio ambientale, stoccaggio di prodotti farmaceutici, trasporto di prodotti alimentari, automazione serre, ecc. Sviluppato in un contenitore AISI 304 con grado di protezione IP65, è adatto per essere impiegato anche in ambienti severi; inoltre le dimensioni estremamente compatte (∅ 14 x 145 mm) e la varietà di uscite disponibili (analogiche 0&#8230;1V, digitali RS232C o RS485 MODBUS-RTU) lo rendono ideale per essere integrato in gran numero di applicazioni OEM. È fornito con software HD9817TC software per la lettura delle misure da PC e la calibrazione del sensore di umidità relativa.</p>
<p>Sono disponibili le seguenti versioni:</p>
<p><strong>HD9817T1R</strong>: Doppio trasmettitore temperatura e umidità relativa. Temperatura sensore Pt100 1/3 DIN. Campo di misura in umidità relativa: 0&#8230;100% UR, in temperatura: -40&#8230;+60 °C. Doppio segnale di uscita 0&#8230;1 Vdc. Alimentazione 5&#8230;30 Vdc. Contenitore in AISI 304, dimensioni ∅ 14 mm, L = 138 mm. Configurazione standard 0&#8230;100% UR = 0&#8230;1 Vdc, -40&#8230;+60 °C = 0&#8230;1 Vdc. Cavo 7 fili più calza L = 1,5 m.</p>
<p><strong>HD9817T2R</strong>: Doppio trasmettitore temperatura e umidità relativa. Temperatura sensore Pt100 1/3 DIN. Campo di misura in umidità relativa: 0&#8230;100 %UR, in temperatura: -40&#8230;+60 °C. Uscita RS232C. Alimentazione non isolata prelevata dall’uscita RS232C del PC. Contenitore in AISI 304, dimensioni ∅ 14 mm, L = 138 mm. Configurazione standard 0&#8230;100 %UR in umidità relativa e -40&#8230;+60 °C in temperatura. Cavo di uscita con connettore DB9 femmina, L = 2 m. Baud rate 2400.</p>
<p><strong>HD9817TVS</strong>:Doppio trasmettitore di umidità e temperatura, sensore Pt100. Uscite analogiche 0&#8230;1 Vdc e uscita RS485 MODBUS-RTU. Campo di misura in temperatura -40&#8230;+60 °C. Alimentazione 5&#8230;30 Vdc. Contenitore AISI 304. Grado di protezione della sonda IP 65. Dimensioni ∅14 x 155 mm. Uscita con connettore M12 a 8 poli maschio. Fornito con cavo CP9817.3, lunghezza 3 m.</p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd9817t-serie-trasmettitori-di-umidita-relativa-o-temperatura-con-uscita-digitale/">HD9817T serie &#8211; Trasmettitori Umidità Relativa e Temperatura</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2817T&#8230;Serie &#8211; Trasmettitori Indicatori con Sonda Intercambiabile</title>
		<link>https://environmental.senseca.com/it/prodotto/hd2817t-serie-trasmettitori-indicatori-con-sonda-intercambiabile/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 31 Jul 2018 14:43:31 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2817t-serie-interchangeable-probe-avctive-transmitters/</guid>

					<description><![CDATA[<p>Trasmettitore, indicatore, regolatore ON/OFF, datalogger di temperatura e umidità con sonda intercambiabile.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2817t-serie-trasmettitori-indicatori-con-sonda-intercambiabile/">HD2817T&#8230;Serie &#8211; Trasmettitori Indicatori con Sonda Intercambiabile</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Gli strumenti della serie HD2817T&#8230; sono dei <strong>trasmettitori, indicatori, regolatori ON/OFF</strong> con funzione <strong>datalogger </strong>e display LCD grafico retroilluminato, per la misura di temperatura e umidità.</p>
<p>Caratteristica principale di questi strumenti è di avere la <strong>sonda intercambiabile.</strong> L’utente può cambiare la sonda praticamente senza interrompere il processo. La sonda in un secondo tempo può essere tarata o riparata.</p>
<p>Sono disponibili modelli con <strong>sonda orizzontale (S.TO)</strong>, <strong>verticale (S.TV)</strong> o con <strong>sonda separata (S.TC)</strong>, connessa allo strumento con cavo di varie lunghezze. Le sonde S.TO e S.TV sono in acciaio AISI304, le sonde S.TC possono essere in AISI304 o materiale plastico.</p>
<p>La sonda, tarata in fabbrica e pronta all’uso, è dotata di un <strong>modulo SICRAM2</strong> che <strong>memorizza i dati di calibrazione della sonda e ne permette l’intercambiabilità.</strong></p>
<p>Gli strumenti misurano:</p>
<ul>
<li>Temperatura in gradi Celsius o Fahrenheit</li>
<li>Umidità relativa</li>
</ul>
<p>e calcolano:</p>
<ul>
<li>Umidità assoluta</li>
<li>Mixing Ratio o rapporto di mescolanza</li>
<li>Dew point o punto di rugiada</li>
<li>Temperatura di bulbo umido.</li>
</ul>
<p>Tutti i modelli hanno uscite analogiche sia in tensione che in corrente.</p>
<p>Sono disponibili modelli con due relè di lavoro ed uno di allarme, configurabili dall’utente. Su tutti i modelli è presente un’uscita multistandard RS232/RS485 ed un’uscita seriale ausiliaria RS232C. Tramite la porta seriale RS485 è possibile collegare più strumenti in una rete. La funzione datalogger permette di memorizzare le misure rilevate dallo strumento, con cadenza prefissata dall’utente.</p>
<p><em>Sonde:</em></p>
<p><strong>Sonda verticale</strong></p>
<p>S.TV – L= 130 mm IN AISI 304</p>
<p><strong>Sonde con cavo</strong></p>
<p>Il materiale delle sonde della serie S.TC… può essere scelto fra <strong>AISI304</strong> <strong>fino a  150 °C o fino a 170 °C (HT nel codice)</strong> o <strong>PBT (P nel codice)</strong>.</p>
<ul>
<li>S.TC1.2 &#8211; S.TC1.2HT e S.TC1.2P – Sonda L = 135 mm con cavo di 2 m</li>
<li>S.TC1.5 &#8211;  S.TC1.5HT e S.TC1.5P – Sonda L = 135 mm con cavo di 5 m</li>
<li>S.TC1.10 &#8211; S.TC1.10HT e S.TC1.10P – Sonda L = 135 mm con cavo di 10 m</li>
<li>S.TC2.2 &#8211; S.TC2.2HT e S.TC2.2P – Sonda L = 335 mm con cavo di 2 m</li>
<li>S.TC2.5 &#8211; S.TC2.5HT e S.TC2.5P – Sonda L = 335 mm con cavo di 5 m</li>
<li>S.TC2.10 &#8211; S.TC2.10HT e S.TC2.10P – Sonda L = 335 mm con cavo di 10 m</li>
</ul>
<p><strong>Sonde orizzontali</strong></p>
<p>S.TO1 – Sonda orizzontale L= 135mm<br />
S.TO2 – Sonda orizzontale L= 335mm</p>
<p>Sonde con cavo per <strong>misure in condotte</strong>: S.TC2.480.2 e S.481.2</p>
<p hidden="">HD2817T.D0, HD2817T.DR, HD2817TO.D0, HD2817TO.DR</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd2817t-serie-trasmettitori-indicatori-con-sonda-intercambiabile/">HD2817T&#8230;Serie &#8211; Trasmettitori Indicatori con Sonda Intercambiabile</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
