<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>thermal comfort Archives - Senseca Italy Srl</title>
	<atom:link href="https://environmental.senseca.com/it/tag-prodotto/thermal-comfort-it/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/it/tag-prodotto/thermal-comfort-it/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Thu, 05 Jun 2025 11:26:04 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>thermal comfort Archives - Senseca Italy Srl</title>
	<link>https://environmental.senseca.com/it/tag-prodotto/thermal-comfort-it/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HD32.2 &#8211; Datalogger per Analisi WBGT</title>
		<link>https://environmental.senseca.com/it/prodotto/hd32-2-datalogger-per-analisi-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-2-datalogger-per-analisi-wbgt/</guid>

					<description><![CDATA[<p>Thermal microclimate per la misura del WBGT Index in ambienti caldi. Portatile.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-2-datalogger-per-analisi-wbgt/">HD32.2 &#8211; Datalogger per Analisi WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD32.2 è stato studiato per l’analisi dell’indice <strong>WBGT (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globo-termometro)</strong> in ambienti caldi in conformità alle norme ISO 7726 e ISO 7243.</p>
<p>Lo strumento è dotato di tre ingressi per sonde con modulo SICRAM: le sonde dispongono di un circuito elettronico che dialoga con lo strumento, nella loro memoria permanente sono conservati i dati di taratura del sensore.<br />
Tutte le sonde SICRAM possono essere inserite in uno qualunque degli ingressi: vengono riconosciute automaticamente all’accensione dello strumento.</p>
<p>Le caratteristiche principali dello strumento sono:</p>
<ul>
<li><strong>Logging:</strong> acquisizione dei dati e memorizzazione all’interno dello strumento. Capacità di memoria: 64 sessioni di logging distinte, con la possibilità di impostare l’intervallo di acquisizione dei campioni. Si può impostare la durata della memorizzazione e, con la funzione auto-start, è possibile impostare la data e l’ora di inizio e di fine di memorizzazione dei dati.</li>
<li>L’unità di misura delle grandezze di temperatura visualizzate: °C, °F, °K.</li>
<li>La data e l’ora del sistema.</li>
<li>La visualizzazione dei parametri statistici massimo, minimo, media e la loro cancellazione.</li>
<li>La velocità di trasferimento dei dati tramite la porta seriale RS232.</li>
</ul>
<p>Lo strumento HD32.2 è in grado di rilevare contemporaneamente le seguenti grandezze:</p>
<ul>
<li><strong>Temperatura di globotermometro Tg.</strong></li>
<li><strong>Temperatura di bulbo umido a ventilazione naturale Tn.</strong></li>
<li><strong>Temperatura ambiente T.</strong></li>
</ul>
<p>Sulla base delle grandezze rilevate HD32.2 è in grado di calcolare:</p>
<ul>
<li><strong>Indice WBGT(in)</strong> (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globotermometro) in assenza di irraggiamento solare.</li>
<li><strong>Indice WBGT(out)</strong> (Wet Bulb Glob Temperature: temperatura a bulbo umido e del globotermometro) in presenza di irraggiamento solare.</li>
</ul>
<p>Sonde necessarie per la misura del WBGT:</p>
<ul>
<li>Sonda di temperatura di bulbo secco TP3207.2.</li>
<li>Sonda di temperatura globotermometro TP3276.2.</li>
<li>Sonda di temperatura di bulbo umido a ventilazione naturale HP3201.2.</li>
</ul>
<p>HD32.2 è la versione portatile, utilizzata per lo più in combinazione con un supporto da tavolo (treppiede piccolo). Per misurazioni di lunga durata si consiglia la versione con treppiede stabile HD32.3A.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-2-datalogger-per-analisi-wbgt/">HD32.2 &#8211; Datalogger per Analisi WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HP3201 &#8211; Sonda Bulbo Umido Ventilazione Naturale</title>
		<link>https://environmental.senseca.com/it/prodotto/hp3201-sonda-bulbo-umido-ventilazione-naturale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hp3201-sonda-bulbo-umido-ventilazione-naturale/</guid>

					<description><![CDATA[<p>Sonda a bulbo umido a ventilazione naturale per misure WBGT. Sensore Pt100.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hp3201-sonda-bulbo-umido-ventilazione-naturale/">HP3201 &#8211; Sonda Bulbo Umido Ventilazione Naturale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Sonda a bulbo umido a ventilazione naturale. Sensore Pt100. Gambo sonda Ø 14 mm, lunghezza 110 mm. Cavo lunghezza 2 m.</p>
<p>Completa di modulo SICRAM, 2 calze di ricambio e contenitore di 50 cc di acqua distillata.</p>
<p>Campo di misura +4 °C…+80 °C.</p>
<p>Impiegata nelle <strong>misure di WBGT </strong>con gli strumenti <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a>, <a href="https://environmental.senseca.com/it/product/hd32-2a-datalogger-per-analisi-wbgt/">HD32.2A</a> e <a href="https://environmental.senseca.com/it/product/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt/">HD32.3TCA</a>.</p>
<p>A richiesta, certificato ACCREDIA temperatura su 4 punti fissi (VACCREDIA-U9).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hp3201-sonda-bulbo-umido-ventilazione-naturale/">HP3201 &#8211; Sonda Bulbo Umido Ventilazione Naturale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3A &#8211; Datalogger per Misure WBGT, PMW, PPD</title>
		<link>https://environmental.senseca.com/it/prodotto/hd32-3a-datalogger-per-misure-wbgt-pmw-ppd/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3a-wbgt-pmw-ppd-measurement/</guid>

					<description><![CDATA[<p>Thermal microclimate per misurare l'indice WBGT, indice PMV (voto medio previsto) e PPD (percentuale prevista di insoddisfatti). 3 ingressi per sonde con modulo SICRAM, display grafico.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-3a-datalogger-per-misure-wbgt-pmw-ppd/">HD32.3A &#8211; Datalogger per Misure WBGT, PMW, PPD</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate per la misura del WBGT Index, PMV Index (voto medio previsto) e PPD percentuale prevista di insoddisfatti. Ingresso 3 canali per sonde con modulo SICRAM, display grafico.</p>
<p>Include software DeltaLog 10 (con analisi indici WBGT, PMV e PPD) scaricabile dal sito web Senseca.</p>
<p>Il kit è composto da strumento HD32.3, 4 batterie AA da 1,5 V, manuale d’istruzioni.</p>
<p>Le sonde e i cavi vanno richiesti a parte.</p>
<p>Le sonde necessarie per la misura del WBGT sono:</p>
<ul>
<li>Sonda di temperatura di bulbo secco TP3207.</li>
<li>Sonda di temperatura globotermometro TP3275.</li>
<li>Sonda di temperatura di bulbo umido a ventilazione naturale HP3201 o TP3204S.</li>
</ul>
<p>Le sonde necessarie per la misura del PMV e PPD sono:</p>
<ul>
<li>Sonda combinata temperatura e umidità relativa HP3217R.</li>
<li>Sonda a filo caldo omnidirezionale AP3203.</li>
<li>Sonda di temperatura globotermometro TP3275.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-3a-datalogger-per-misure-wbgt-pmw-ppd/">HD32.3A &#8211; Datalogger per Misure WBGT, PMW, PPD</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HP3217DM &#8211; Sonda doppia per Analisi Microclimatiche</title>
		<link>https://environmental.senseca.com/it/prodotto/hp3217dm-sonda-doppia-per-analisi-microclimatiche/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:22:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hp3217dm-sonda-doppia-per-analisi-microclimatiche/</guid>

					<description><![CDATA[<p>Sonda doppia a bulbo umido a ventilazione naturale e sonda di temperatura (bulbo secco).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hp3217dm-sonda-doppia-per-analisi-microclimatiche/">HP3217DM &#8211; Sonda doppia per Analisi Microclimatiche</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Sonda doppia a bulbo umido a ventilazione naturale e sonda di temperatura (bulbo secco) per stazione microclimatica <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a></p>
<p>Gambo sonda Ø 14 mm, lunghezza 110 mm. Cavo lunghezza 2 m. Completa di modulo SICRAM doppio, di ricambio della calza e contenitore di 50 cc di acqua distillata.</p>
<p>Campo di misura +4 °C…+80 °C.</p>
<p>A richiesta, 2 certificati ACCREDIA temperatura, uno per ciascuna sonda, su 4 punti fissi (VACCREDIA-U9).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hp3217dm-sonda-doppia-per-analisi-microclimatiche/">HP3217DM &#8211; Sonda doppia per Analisi Microclimatiche</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3207TR &#8211; Sonda Temperatura Radiante</title>
		<link>https://environmental.senseca.com/it/prodotto/tp3207tr-sonda-temperatura-radiante/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:23:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3207tr-sonda-temperatura-radiante/</guid>

					<description><![CDATA[<p>Sonda per la misura della temperatura radiante, utilizzata per la valutazione degli insoddisfatti da asimmetria radiante.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3207tr-sonda-temperatura-radiante/">TP3207TR &#8211; Sonda Temperatura Radiante</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Sonda per la misura della<strong> temperatura radiante.</strong></p>
<p>Gambo sonda Ø 16 mm, lunghezza 250 mm. Cavo lunghezza 2 m. Completa di modulo SICRAM.</p>
<p>Campo di misura 0 °C…+60 °C.</p>
<p>Impiegata con la stazione microclimatica HD32.1, viene utilizzata per la valutazione degli insoddisfatti da asimmetria radiante.</p>
<p>A richiesta, rapporto di taratura ISO per LPNET07 (VCERT-L26).)</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3207tr-sonda-temperatura-radiante/">TP3207TR &#8211; Sonda Temperatura Radiante</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3276 &#8211; Sonda di Temperatura Globotermometro</title>
		<link>https://environmental.senseca.com/it/prodotto/tp3276-sonda-di-temperatura-globotermometro/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:23:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3276-sonda-di-temperatura-globotermometro/</guid>

					<description><![CDATA[<p>Sonda di temperatura globotermometro sensore Pt100, globo Ø 50 mm, cavo 2 m con modulo SICRAM</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3276-sonda-di-temperatura-globotermometro/">TP3276 &#8211; Sonda di Temperatura Globotermometro</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Sonda di temperatura globotermometro sensore Pt100, globo Ø 50 mm. Gambo Ø 8 mm, lunghezza 110 mm. Cavo lunghezza 2 metri. Completa di modulo SICRAM.</p>
<p>Campo di misura -30 °C&#8230;+120 °C.</p>
<p>Utilizzata con la stazione microclimatica HD32.1, la sonda viene impiegata per il calcolo dei seguenti indici:</p>
<ul>
<li><strong>Mean radiant temperature:</strong> in combinazione con la sonda di temperatura dell&#8217;aria e la sonda a filo caldo per la velocità del vento.</li>
<li><strong>WBGT: </strong>in combinazione con la sonda di temperatura a bulbo umido e ventilazione naturale e la sonda di temperatura a bulbo secco.</li>
</ul>
<p>A richiesta, certificato ACCREDIA temperatura su 4 punti fissi (VACCREDIA-U9).</p>
<p>Disponiblile anche solo globo di ricambio Ø 50 mm (codice: TP876S)</p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3276-sonda-di-temperatura-globotermometro/">TP3276 &#8211; Sonda di Temperatura Globotermometro</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3227K &#8211; Sonda di Temperatura Discomfort Locale</title>
		<link>https://environmental.senseca.com/it/prodotto/tp3227k-sonda-di-temperatura-discomfort-locale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:23:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3227k-sonda-di-temperatura-discomfort-locale/</guid>

					<description><![CDATA[<p>Sonda di temperatura composta da 2 sonde indipendenti, sensore Pt100. Impiegata nelle misure del discomfort locale dovuto a gradiente verticale di temperatura.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3227k-sonda-di-temperatura-discomfort-locale/">TP3227K &#8211; Sonda di Temperatura Discomfort Locale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Sonda di temperatura composta da 2 sonde indipendenti, sensore Pt100.</p>
<p>Diametro gambo Ø 14 mm, lunghezza 500 mm. Cavo lunghezza 2 metri. Completa di modulo SICRAM doppio e asta prolunga Ø 14 mm, lunghezza 450 mm TP3227.2.</p>
<p>Campo di misura -10 °C&#8230;+100 °C.</p>
<p>In combinazione con altre sonde, è impiegata nelle misure del<strong> discomfort locale dovuto a gradiente verticale di temperatura</strong>. Si può utilizzare per lo s<strong>tudio relativo a soggetti in piedi o seduti</strong>. L’altezza di una sonda è regolabile.</p>
<p>Utilizzata con il datalogger per la misura del microclima HD32.1.</p>
<p>A richiesta, 2 certificati ACCREDIA temperatura, uno per ciascuna sonda, su 4 punti fissi (VACCREDIA-UT4).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3227k-sonda-di-temperatura-discomfort-locale/">TP3227K &#8211; Sonda di Temperatura Discomfort Locale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3227PC &#8211; Sonda di Temperatura Discomfort Locale</title>
		<link>https://environmental.senseca.com/it/prodotto/tp3227pc-sonda-di-temperatura-discomfort-locale/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 14:23:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3227pc-sonda-di-temperatura-discomfort-locale/</guid>

					<description><![CDATA[<p>Sonda di temperatura composta da 2 sonde indipendenti, sensore Pt100 impiegata nelle misure del discomfort locale dovuto a gradiente verticale di temperatura.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3227pc-sonda-di-temperatura-discomfort-locale/">TP3227PC &#8211; Sonda di Temperatura Discomfort Locale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Sonda di temperatura composta da 2 sonde indipendenti, sensore Pt100, uno per la misura della temperatura del pavimento (diametro Ø 70 mm, altezza 30 mm), l’altro per la misura della temperatura all’altezza delle caviglie (diametro Ø 3 mm, altezza 100 mm). Cavo lunghezza 2 metri. Completa di modulo SICRAM doppio.</p>
<p>Campo di misura -10 °C…+100 °C.</p>
<p>Impiegata nelle misure del <strong>discomfort locale dovuto a gradiente verticale di temperatura</strong> con datalogger HD32.1.</p>
<p>A richiesta, 2 certificati ACCREDIA temperatura, uno per ciascuna sonda, su 4 punti fissi (VACCREDIA-U9).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/tp3227pc-sonda-di-temperatura-discomfort-locale/">TP3227PC &#8211; Sonda di Temperatura Discomfort Locale</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3TC &#8211; HD32.3TCA &#8211; Microclima Termico PMV-PPD / WBGT</title>
		<link>https://environmental.senseca.com/it/prodotto/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 24 Mar 2020 16:37:40 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/</guid>

					<description><![CDATA[<p>Datalogger portatile indicato per l’analisi del microclima e della qualità dell’aria in ambienti interni (Indoor Air Quality, IAQ).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt/">HD32.3TC &#8211; HD32.3TCA &#8211; Microclima Termico PMV-PPD / WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate per la misura degli indici <strong>WBGT, PMV</strong> (voto medio previsto), <strong>PPD</strong> (percentuale prevista di insoddisfatti), <strong>DR</strong> (disturbo da correnti d’aria), <strong>TU</strong> (intensità locale di turbolenza), HI (indice di calore), <strong>UTCI</strong> (Universal Thermal Climate Index), <strong>TEP</strong> (Temperatura equivalente percepita), <strong>CO<sub>2</sub>, PM1.0, PM2.5</strong> e <strong>PM10</strong>. Stima del tempo di decadimento <strong>SARS-CoV-2</strong> sulle superfici.</p>
<p><strong>HD32.3TC</strong> è la versione portatile, usata per lo più in combinazione con un supporto da tavolo (piccolo treppiede).<br />
<strong>HD32.3TCA</strong> è la versione che si usa con un treppiede stabile, adatto ad essere usato per misurazioni per periodo più prolungati.</p>
<p>Tecnicamente la differenza è semplice: con<strong> HD32.3TCA i sensori sono collegati da un cavo</strong> e viene utilizzato un globotermometro con ∅150 mm. Con la versione HD32.3TC il globotermometro è di ∅50 mm e <strong>i sensori vengono collegati direttamente</strong> nella parte superiore dello strumento.</p>
<p>Entrambi sono completamente conformi alle norme<strong> ISO7730, ISO7726 e ISO7243</strong>.</p>
<p>A seconda delle sonde collegate, HD32.3TC(A) misurano simultaneamente:</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li><strong>T</strong> temperatura di bulbo secco</li>
<li><strong>T<sub>nw</sub></strong> temperatura di bulbo umido a ventilazione naturale</li>
<li><strong>T<sub>g</sub></strong> temperatura di globotermometro</li>
<li><strong>UR</strong> umidità relativa</li>
<li><strong>V<sub>a</sub></strong> velocità dell’aria</li>
<li><strong>CO<sub>2</sub></strong> biossido di carbonio</li>
<li><strong>P<sub>atm</sub></strong> pressione atmosferica</li>
<li><strong>PM1.0, PM2.5, PM10</strong> polveri sottili</li>
</ul>
</li>
</ul>
<p>Un display touch chiaro e luminoso permette di visualizzare direttamente i valori calcolati per WBGT, PMV/PPD e TU. I dati sono immediatamente disponibili tramite l&#8217;applicazione &#8220;cloud&#8221; accessibile da remoto tramite connessione Wi-Fi. Il datalogger ha una grande capacità di memoria per cicli di misurazione di lunga durata. Inoltre, la batteria ricaricabile garantisce un&#8217;autonomia di lavoro di almeno 24 ore.</p>
<p>Norme di riferimento: <strong>ISO 7726 &#8211;  </strong>Ergonomics of the thermal environment &#8211; Instruments for measuring physical quantities. <strong>ISO 7730 &#8211;  </strong>Ergonomics of the thermal environment &#8211; Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. <strong>ISO 7243 &#8211; </strong>Ergonomics of the thermal environment &#8211; Assessment of heat stress using the WBGT (wet bulb globe temperature) index. <strong>ASHRAE Standard 55 &#8211; </strong>Thermal Environmental Conditions for Human Occupancy. <strong>ASHRAE Standard 62.1-2019 &#8211; </strong>Ventilation for Acceptable Indoor Air Quality. <strong>ASHRAE Standard 62.1-2019 &#8211; </strong>Ventilation for Acceptable Indoor Air Quality.</p>
<p>Gli strumenti HD32.3TC e HD32.3TCA misurano e calcolano un numero di indici superiore rispetto agli strumenti HD32.3 e HD32.3A. La vendita, la riparazione e la manutenzione della vecchia serie rimangono comunque disponibili.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/it/prodotto/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt/">HD32.3TC &#8211; HD32.3TCA &#8211; Microclima Termico PMV-PPD / WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com/it/">Senseca Italy Srl</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
