{"id":16593,"date":"2026-01-21T13:41:47","date_gmt":"2026-01-21T13:41:47","guid":{"rendered":"https:\/\/environmental.senseca.com\/?p=16593"},"modified":"2026-01-21T13:45:53","modified_gmt":"2026-01-21T13:45:53","slug":"uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio","status":"publish","type":"post","link":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/","title":{"rendered":"UNI 11988:2025 &#8211; Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio"},"content":{"rendered":"<h3 data-start=\"0\" data-end=\"26\">Una panoramica tecnica<\/h3>\n<p data-start=\"28\" data-end=\"486\"><strong data-start=\"28\" data-end=\"46\">UNI 11988:2025<\/strong> \u00e8 una norma nazionale italiana pubblicata da <strong data-start=\"92\" data-end=\"129\">UNI (Ente Italiano di Normazione)<\/strong>. Definisce i <strong data-start=\"143\" data-end=\"176\">requisiti tecnici e operativi<\/strong> per i sistemi di <strong data-start=\"194\" data-end=\"240\">Emergency Voice Alarm Communication (EVAC)<\/strong> interfacciati con i sistemi di <strong data-start=\"272\" data-end=\"295\">rivelazione incendi<\/strong> e <strong data-start=\"298\" data-end=\"318\">allarme incendio<\/strong>. Pubblicata nel 2025, la norma fornisce un quadro di riferimento completo per contribuire a garantire una <strong data-start=\"425\" data-end=\"462\">comunicazione vocale di emergenza<\/strong> efficace negli edifici.<\/p>\n<h2 data-start=\"493\" data-end=\"512\">Scopo e contesto<\/h2>\n<p data-start=\"514\" data-end=\"1100\">I tradizionali allarmi acustici (sirene o campane) possono non offrire indicazioni sufficienti durante un\u2019emergenza, soprattutto in <strong data-start=\"646\" data-end=\"667\">edifici complessi<\/strong> o in ambienti <strong data-start=\"682\" data-end=\"695\">affollati<\/strong>. <strong data-start=\"697\" data-end=\"715\">UNI 11988:2025<\/strong> colma questa lacuna disciplinando sistemi in grado di diffondere <strong data-start=\"781\" data-end=\"823\">messaggi vocali chiari e intelligibili<\/strong> agli occupanti, favorendo evacuazioni <strong data-start=\"862\" data-end=\"887\">pi\u00f9 rapide e ordinate<\/strong> e riducendo il rischio di panico. La norma riflette i principi pi\u00f9 moderni dell\u2019<strong data-start=\"968\" data-end=\"1010\">ingegneria della sicurezza antincendio<\/strong> e si allinea agli approcci di sicurezza <strong data-start=\"1051\" data-end=\"1099\">basati sulle prestazioni (performance-based)<\/strong>.<\/p>\n<h2 data-start=\"1107\" data-end=\"1131\">Campo di applicazione<\/h2>\n<p data-start=\"1133\" data-end=\"1327\">La norma si applica ai sistemi <strong data-start=\"1164\" data-end=\"1172\">EVAC<\/strong> di <strong data-start=\"1176\" data-end=\"1221\">nuova progettazione e nuova installazione<\/strong> integrati con sistemi fissi di rivelazione incendi. Copre l\u2019intero ciclo di vita dei sistemi, includendo:<\/p>\n<ul data-start=\"1329\" data-end=\"1560\">\n<li data-start=\"1329\" data-end=\"1392\">\n<p data-start=\"1331\" data-end=\"1392\"><strong data-start=\"1331\" data-end=\"1360\">Progettazione del sistema<\/strong> e <strong data-start=\"1363\" data-end=\"1390\">pianificazione acustica<\/strong><\/p>\n<\/li>\n<li data-start=\"1393\" data-end=\"1445\">\n<p data-start=\"1395\" data-end=\"1445\"><strong data-start=\"1395\" data-end=\"1412\">Installazione<\/strong> e <strong data-start=\"1415\" data-end=\"1431\">integrazione<\/strong> del sistema<\/p>\n<\/li>\n<li data-start=\"1446\" data-end=\"1510\">\n<p data-start=\"1448\" data-end=\"1510\"><strong data-start=\"1448\" data-end=\"1485\">Messa in servizio (commissioning)<\/strong> e <strong data-start=\"1488\" data-end=\"1508\">prove funzionali<\/strong><\/p>\n<\/li>\n<li data-start=\"1511\" data-end=\"1560\">\n<p data-start=\"1513\" data-end=\"1560\"><strong data-start=\"1513\" data-end=\"1526\">Esercizio<\/strong>, <strong data-start=\"1528\" data-end=\"1541\">ispezione<\/strong> e <strong data-start=\"1544\" data-end=\"1560\">manutenzione<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1562\" data-end=\"1671\">Sono esplicitamente esclusi i <strong data-start=\"1592\" data-end=\"1641\">semplici dispositivi di segnalazione acustica<\/strong> privi di funzionalit\u00e0 vocale.<\/p>\n<h2 data-start=\"1678\" data-end=\"1704\">Principi tecnici chiave<\/h2>\n<p data-start=\"1706\" data-end=\"2148\">UNI 11988:2025 pone forte enfasi su <strong data-start=\"1742\" data-end=\"1773\">intelligibilit\u00e0 del parlato<\/strong>, <strong data-start=\"1775\" data-end=\"1803\">affidabilit\u00e0 del sistema<\/strong>, <strong data-start=\"1805\" data-end=\"1819\">ridondanza<\/strong> e <strong data-start=\"1822\" data-end=\"1855\">continuit\u00e0 dell\u2019alimentazione<\/strong> durante l\u2019emergenza. Definisce criteri per <strong data-start=\"1899\" data-end=\"1931\">posizionamento dei diffusori<\/strong>, <strong data-start=\"1933\" data-end=\"1949\">zonizzazione<\/strong>, <strong data-start=\"1951\" data-end=\"1976\">priorit\u00e0 dei messaggi<\/strong> e <strong data-start=\"1979\" data-end=\"2033\">coordinamento con la logica di rivelazione incendi<\/strong>. Le procedure di <strong data-start=\"2051\" data-end=\"2074\">verifica e collaudo<\/strong> contribuiscono a mantenere costanti le prestazioni del sistema nel tempo.<\/p>\n<h2 data-start=\"2155\" data-end=\"2200\">Verifica acustica: cosa si misura in campo<\/h2>\n<p data-start=\"2202\" data-end=\"2319\">Per confermare che i messaggi vocali siano trasmessi in modo efficace, le attivit\u00e0 di verifica includono tipicamente:<\/p>\n<ul data-start=\"2321\" data-end=\"2726\">\n<li data-start=\"2321\" data-end=\"2415\">\n<p data-start=\"2323\" data-end=\"2415\">misura del <strong data-start=\"2334\" data-end=\"2371\">livello di pressione sonora (SPL)<\/strong> dei messaggi EVAC in punti rappresentativi;<\/p>\n<\/li>\n<li data-start=\"2416\" data-end=\"2504\">\n<p data-start=\"2418\" data-end=\"2504\">misura di <strong data-start=\"2428\" data-end=\"2437\">STIPA<\/strong> e del <strong data-start=\"2444\" data-end=\"2476\">tempo di riverberazione RT60<\/strong> nelle aree acustiche (ADA);<\/p>\n<\/li>\n<li data-start=\"2505\" data-end=\"2625\">\n<p data-start=\"2507\" data-end=\"2625\">misura del <strong data-start=\"2518\" data-end=\"2537\">rumore di fondo<\/strong>, includendo (quando pertinente) il contributo degli impianti tecnologici dell\u2019edificio;<\/p>\n<\/li>\n<li data-start=\"2626\" data-end=\"2726\">\n<p data-start=\"2628\" data-end=\"2726\">verifica del <strong data-start=\"2641\" data-end=\"2667\">margine segnale\/rumore<\/strong>, che influisce direttamente sulla chiarezza del messaggio.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2728\" data-end=\"3197\">Quando necessario, l\u2019analisi in <strong data-start=\"2760\" data-end=\"2798\">bande d\u2019ottava o di terzo d\u2019ottava<\/strong> aiuta a individuare criticit\u00e0 legate alla distribuzione in frequenza e a supportare eventuali azioni correttive (ad esempio <strong data-start=\"2923\" data-end=\"2949\">taratura dei diffusori<\/strong>, regolazioni di <strong data-start=\"2966\" data-end=\"2982\">zonizzazione<\/strong> o modifiche del <strong data-start=\"2999\" data-end=\"3017\">posizionamento<\/strong>). I risultati delle prove dovrebbero essere <strong data-start=\"3062\" data-end=\"3088\">registrati e riportati<\/strong> per garantire la ripetibilit\u00e0 nel tempo e supportare sia la <strong data-start=\"3149\" data-end=\"3170\">messa in servizio<\/strong> sia i controlli periodici.<\/p>\n<h2 data-start=\"3204\" data-end=\"3239\">Destinatari e valore applicativo<\/h2>\n<p data-start=\"3241\" data-end=\"3702\">Pur essendo volontaria, <strong data-start=\"3265\" data-end=\"3283\">UNI 11988:2025<\/strong> rappresenta una <strong data-start=\"3300\" data-end=\"3330\">best practice riconosciuta<\/strong> nella progettazione della sicurezza antincendio in Italia. \u00c8 rivolta a <strong data-start=\"3402\" data-end=\"3432\">professionisti antincendio<\/strong>, <strong data-start=\"3434\" data-end=\"3449\">progettisti<\/strong>, <strong data-start=\"3451\" data-end=\"3467\">installatori<\/strong>, <strong data-start=\"3469\" data-end=\"3503\">proprietari\/gestori di edifici<\/strong> e <strong data-start=\"3506\" data-end=\"3529\">autorit\u00e0 competenti<\/strong>. L\u2019adozione della norma supporta l\u2019allineamento ai requisiti applicabili, aumenta la <strong data-start=\"3615\" data-end=\"3644\">sicurezza degli occupanti<\/strong> e migliora l\u2019efficacia della <strong data-start=\"3674\" data-end=\"3701\">gestione dell\u2019emergenza<\/strong>.<\/p>\n<h2 data-start=\"3709\" data-end=\"3723\">Conclusione<\/h2>\n<p data-start=\"3725\" data-end=\"4043\">UNI 11988:2025 segna un passo importante verso una <strong data-start=\"3776\" data-end=\"3833\">comunicazione di emergenza pi\u00f9 sicura e intelligibile<\/strong> negli edifici. Standardizzando progettazione, verifica e gestione dei sistemi <strong data-start=\"3912\" data-end=\"3920\">EVAC<\/strong>, contribuisce a elevare i livelli di <strong data-start=\"3958\" data-end=\"3983\">sicurezza antincendio<\/strong> e a rendere le evacuazioni pi\u00f9 <strong data-start=\"4015\" data-end=\"4042\">controllate ed efficaci<\/strong>.<\/p>\n<p data-start=\"4045\" data-end=\"4406\">Per supportare l\u2019implementazione della norma, il <strong data-start=\"4094\" data-end=\"4131\">fonometro Senseca XPT800 Classe 1<\/strong> aiuta i professionisti nella <strong data-start=\"4161\" data-end=\"4218\">verifica delle prestazioni acustiche dei sistemi EVAC<\/strong>, grazie a misure accurate del <strong data-start=\"4249\" data-end=\"4269\">SPL dei messaggi<\/strong> e del <strong data-start=\"4276\" data-end=\"4295\">rumore di fondo<\/strong>, consentendo una <strong data-start=\"4313\" data-end=\"4338\">reportistica coerente<\/strong> e una <strong data-start=\"4345\" data-end=\"4377\">documentazione dei risultati<\/strong> in linea con UNI 11988:2025.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Una panoramica tecnica UNI 11988:2025 \u00e8 una norma nazionale italiana pubblicata da UNI (Ente Italiano di Normazione). Definisce i requisiti tecnici e operativi per i sistemi di Emergency Voice Alarm Communication (EVAC) interfacciati con i sistemi di rivelazione incendi e allarme incendio. Pubblicata nel 2025, la norma fornisce un quadro di riferimento completo per contribuire a garantire una comunicazione vocale [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":16590,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[787],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio - Senseca Environmental<\/title>\n<meta name=\"description\" content=\"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio. Scopri di pi\u00f9 sulle verifiche acustiche in campo (SPL, STIPA, RT60) con i fonometri UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio - Senseca Environmental\" \/>\n<meta property=\"og:description\" content=\"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio. Scopri di pi\u00f9 sulle verifiche acustiche in campo (SPL, STIPA, RT60) con i fonometri UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio\" \/>\n<meta property=\"og:url\" content=\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\" \/>\n<meta property=\"og:site_name\" content=\"Senseca Italy Srl\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-21T13:41:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-21T13:45:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2026\/01\/UNI11988_SLM_per_news.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Senseca\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Senseca\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\"},\"author\":{\"name\":\"Senseca\",\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/person\/247e7c423692f473cdbd5fe2f60fa33c\"},\"headline\":\"UNI 11988:2025 &#8211; Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio\",\"datePublished\":\"2026-01-21T13:41:47+00:00\",\"dateModified\":\"2026-01-21T13:45:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\"},\"wordCount\":565,\"publisher\":{\"@id\":\"https:\/\/environmental.senseca.com\/#organization\"},\"articleSection\":[\"News\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\",\"url\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\",\"name\":\"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio - Senseca Environmental\",\"isPartOf\":{\"@id\":\"https:\/\/environmental.senseca.com\/#website\"},\"datePublished\":\"2026-01-21T13:41:47+00:00\",\"dateModified\":\"2026-01-21T13:45:53+00:00\",\"description\":\"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio. Scopri di pi\u00f9 sulle verifiche acustiche in campo (SPL, STIPA, RT60) con i fonometri UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio\",\"breadcrumb\":{\"@id\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/environmental.senseca.com\/it\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"UNI 11988:2025 &#8211; Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/environmental.senseca.com\/#website\",\"url\":\"https:\/\/environmental.senseca.com\/\",\"name\":\"Senseca Italy Srl\",\"description\":\"Member of GHM GROUP\",\"publisher\":{\"@id\":\"https:\/\/environmental.senseca.com\/#organization\"},\"alternateName\":\"Senseca\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/environmental.senseca.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/environmental.senseca.com\/#organization\",\"name\":\"Senseca Italy Srl\",\"url\":\"https:\/\/environmental.senseca.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg\",\"contentUrl\":\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg\",\"width\":1000,\"height\":1000,\"caption\":\"Senseca Italy Srl\"},\"image\":{\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/senseca-measurement-solutions\/\",\"https:\/\/www.youtube.com\/@senseca-measurement-solutions\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/person\/247e7c423692f473cdbd5fe2f60fa33c\",\"name\":\"Senseca\",\"url\":\"https:\/\/environmental.senseca.com\/it\/author\/c-casotto\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio - Senseca Environmental","description":"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio. Scopri di pi\u00f9 sulle verifiche acustiche in campo (SPL, STIPA, RT60) con i fonometri UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/","og_locale":"it_IT","og_type":"article","og_title":"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio - Senseca Environmental","og_description":"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio. Scopri di pi\u00f9 sulle verifiche acustiche in campo (SPL, STIPA, RT60) con i fonometri UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio","og_url":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/","og_site_name":"Senseca Italy Srl","article_published_time":"2026-01-21T13:41:47+00:00","article_modified_time":"2026-01-21T13:45:53+00:00","og_image":[{"width":1024,"height":768,"url":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2026\/01\/UNI11988_SLM_per_news.jpg","type":"image\/jpeg"}],"author":"Senseca","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Senseca","Tempo di lettura stimato":"3 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/#article","isPartOf":{"@id":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/"},"author":{"name":"Senseca","@id":"https:\/\/environmental.senseca.com\/#\/schema\/person\/247e7c423692f473cdbd5fe2f60fa33c"},"headline":"UNI 11988:2025 &#8211; Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio","datePublished":"2026-01-21T13:41:47+00:00","dateModified":"2026-01-21T13:45:53+00:00","mainEntityOfPage":{"@id":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/"},"wordCount":565,"publisher":{"@id":"https:\/\/environmental.senseca.com\/#organization"},"articleSection":["News"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/","url":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/","name":"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio - Senseca Environmental","isPartOf":{"@id":"https:\/\/environmental.senseca.com\/#website"},"datePublished":"2026-01-21T13:41:47+00:00","dateModified":"2026-01-21T13:45:53+00:00","description":"UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio. Scopri di pi\u00f9 sulle verifiche acustiche in campo (SPL, STIPA, RT60) con i fonometri UNI 11988:2025 - Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio","breadcrumb":{"@id":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/environmental.senseca.com\/it\/2026\/01\/21\/uni-119882025-sistemi-di-allarme-vocale-di-emergenza-evac-per-la-sicurezza-antincendio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/environmental.senseca.com\/it\/"},{"@type":"ListItem","position":2,"name":"UNI 11988:2025 &#8211; Sistemi di allarme vocale di emergenza (EVAC) per la sicurezza antincendio"}]},{"@type":"WebSite","@id":"https:\/\/environmental.senseca.com\/#website","url":"https:\/\/environmental.senseca.com\/","name":"Senseca Italy Srl","description":"Member of GHM GROUP","publisher":{"@id":"https:\/\/environmental.senseca.com\/#organization"},"alternateName":"Senseca","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/environmental.senseca.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/environmental.senseca.com\/#organization","name":"Senseca Italy Srl","url":"https:\/\/environmental.senseca.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/","url":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg","contentUrl":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg","width":1000,"height":1000,"caption":"Senseca Italy Srl"},"image":{"@id":"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/senseca-measurement-solutions\/","https:\/\/www.youtube.com\/@senseca-measurement-solutions"]},{"@type":"Person","@id":"https:\/\/environmental.senseca.com\/#\/schema\/person\/247e7c423692f473cdbd5fe2f60fa33c","name":"Senseca","url":"https:\/\/environmental.senseca.com\/it\/author\/c-casotto\/"}]}},"_links":{"self":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/posts\/16593"}],"collection":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/comments?post=16593"}],"version-history":[{"count":1,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/posts\/16593\/revisions"}],"predecessor-version":[{"id":16594,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/posts\/16593\/revisions\/16594"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/media\/16590"}],"wp:attachment":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/media?parent=16593"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/categories?post=16593"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/tags?post=16593"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}