{"id":12530,"date":"2020-03-24T16:37:40","date_gmt":"2020-03-24T16:37:40","guid":{"rendered":"https:\/\/www.deltaohm.com\/product\/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt\/"},"modified":"2025-06-05T11:26:04","modified_gmt":"2025-06-05T11:26:04","slug":"hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt","status":"publish","type":"product","link":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/","title":{"rendered":"HD32.3TC &#8211; HD32.3TCA &#8211; Microclima Termico PMV-PPD \/ WBGT"},"content":{"rendered":"<p>Thermal microclimate per la misura degli indici <strong>WBGT, PMV<\/strong> (voto medio previsto), <strong>PPD<\/strong> (percentuale prevista di insoddisfatti), <strong>DR<\/strong> (disturbo da correnti d\u2019aria), <strong>TU<\/strong> (intensit\u00e0 locale di turbolenza), HI (indice di calore), <strong>UTCI<\/strong> (Universal Thermal Climate Index), <strong>TEP<\/strong> (Temperatura equivalente percepita), <strong>CO<sub>2<\/sub>, PM1.0, PM2.5<\/strong> e <strong>PM10<\/strong>. Stima del tempo di decadimento <strong>SARS-CoV-2<\/strong> sulle superfici.<\/p>\n<p><strong>HD32.3TC<\/strong> \u00e8 la versione portatile, usata per lo pi\u00f9 in combinazione con un supporto da tavolo (piccolo treppiede).<br \/>\n<strong>HD32.3TCA<\/strong> \u00e8 la versione che si usa con un treppiede stabile, adatto ad essere usato per misurazioni per periodo pi\u00f9 prolungati.<\/p>\n<p>Tecnicamente la differenza \u00e8 semplice: con<strong> HD32.3TCA i sensori sono collegati da un cavo<\/strong> e viene utilizzato un globotermometro con \u2205150 mm. Con la versione HD32.3TC il globotermometro \u00e8 di \u220550 mm e <strong>i sensori vengono collegati direttamente<\/strong> nella parte superiore dello strumento.<\/p>\n<p>Entrambi sono completamente conformi alle norme<strong> ISO7730, ISO7726 e ISO7243<\/strong>.<\/p>\n<p>A seconda delle sonde collegate, HD32.3TC(A) misurano simultaneamente:<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>T<\/strong> temperatura di bulbo secco<\/li>\n<li><strong>T<sub>nw<\/sub><\/strong> temperatura di bulbo umido a ventilazione naturale<\/li>\n<li><strong>T<sub>g<\/sub><\/strong> temperatura di globotermometro<\/li>\n<li><strong>UR<\/strong> umidit\u00e0 relativa<\/li>\n<li><strong>V<sub>a<\/sub><\/strong> velocit\u00e0 dell\u2019aria<\/li>\n<li><strong>CO<sub>2<\/sub><\/strong> biossido di carbonio<\/li>\n<li><strong>P<sub>atm<\/sub><\/strong> pressione atmosferica<\/li>\n<li><strong>PM1.0, PM2.5, PM10<\/strong> polveri sottili<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Un display touch chiaro e luminoso permette di visualizzare direttamente i valori calcolati per WBGT, PMV\/PPD e TU. I dati sono immediatamente disponibili tramite l&#8217;applicazione &#8220;cloud&#8221; accessibile da remoto tramite connessione Wi-Fi. Il datalogger ha una grande capacit\u00e0 di memoria per cicli di misurazione di lunga durata. Inoltre, la batteria ricaricabile garantisce un&#8217;autonomia di lavoro di almeno 24 ore.<\/p>\n<p>Norme di riferimento: <strong>ISO\u00a07726 &#8211;\u00a0\u00a0<\/strong>Ergonomics of the thermal environment &#8211; Instruments for measuring physical quantities. <strong>ISO\u00a07730 &#8211;\u00a0\u00a0<\/strong>Ergonomics of the thermal environment &#8211; Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. <strong>ISO\u00a07243 &#8211;\u00a0<\/strong>Ergonomics of the thermal environment &#8211; Assessment of heat stress using the WBGT (wet bulb globe temperature) index. <strong>ASHRAE Standard 55 &#8211;\u00a0<\/strong>Thermal Environmental Conditions for Human Occupancy. <strong>ASHRAE Standard 62.1-2019 &#8211;\u00a0<\/strong>Ventilation for Acceptable Indoor Air Quality. <strong>ASHRAE Standard 62.1-2019 &#8211;\u00a0<\/strong>Ventilation for Acceptable Indoor Air Quality.<\/p>\n<p>Gli strumenti HD32.3TC e HD32.3TCA misurano e calcolano un numero di indici superiore rispetto agli strumenti HD32.3 e HD32.3A. La vendita, la riparazione e la manutenzione della vecchia serie rimangono comunque disponibili.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Datalogger portatile indicato per l\u2019analisi del microclima e della qualit\u00e0 dell\u2019aria in ambienti interni (Indoor Air Quality, IAQ).<\/p>\n","protected":false},"featured_media":16285,"template":"","meta":[],"product_cat":[805],"product_tag":[983,982,979,984,981,985,986,980],"brands":[{"id":1215,"name":"Microclima-Thermal Comfort","slug":"microclima-thermal-comfort"}],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT - Microclima-Thermal Comfort - Senseca Italy Srl<\/title>\n<meta name=\"description\" content=\"Cerchi Microclima-Thermal Comfort? Scopri le caratteristiche di HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT di Senseca Italy Srl\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT - Microclima-Thermal Comfort - Senseca Italy Srl\" \/>\n<meta property=\"og:description\" content=\"Cerchi Microclima-Thermal Comfort? Scopri le caratteristiche di HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT di Senseca Italy Srl\" \/>\n<meta property=\"og:url\" content=\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/\" \/>\n<meta property=\"og:site_name\" content=\"Senseca Italy Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-05T11:26:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2020\/03\/img_fam_HD32.3TC_tripod-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1001\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/\",\"url\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/\",\"name\":\"HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT - Microclima-Thermal Comfort - Senseca Italy Srl\",\"isPartOf\":{\"@id\":\"https:\/\/environmental.senseca.com\/#website\"},\"datePublished\":\"2020-03-24T16:37:40+00:00\",\"dateModified\":\"2025-06-05T11:26:04+00:00\",\"description\":\"Cerchi Microclima-Thermal Comfort? Scopri le caratteristiche di HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT di Senseca Italy Srl\",\"breadcrumb\":{\"@id\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/environmental.senseca.com\/it\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Prodotti\",\"item\":\"https:\/\/environmental.senseca.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HD32.3TC &#8211; HD32.3TCA &#8211; Microclima Termico PMV-PPD \/ WBGT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/environmental.senseca.com\/#website\",\"url\":\"https:\/\/environmental.senseca.com\/\",\"name\":\"Senseca Italy Srl\",\"description\":\"Member of GHM GROUP\",\"publisher\":{\"@id\":\"https:\/\/environmental.senseca.com\/#organization\"},\"alternateName\":\"Senseca\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/environmental.senseca.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/environmental.senseca.com\/#organization\",\"name\":\"Senseca Italy Srl\",\"url\":\"https:\/\/environmental.senseca.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg\",\"contentUrl\":\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg\",\"width\":1000,\"height\":1000,\"caption\":\"Senseca Italy Srl\"},\"image\":{\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/senseca-measurement-solutions\/\",\"https:\/\/www.youtube.com\/@senseca-measurement-solutions\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT - Microclima-Thermal Comfort - Senseca Italy Srl","description":"Cerchi Microclima-Thermal Comfort? Scopri le caratteristiche di HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT di Senseca Italy Srl","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/","og_locale":"it_IT","og_type":"article","og_title":"HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT - Microclima-Thermal Comfort - Senseca Italy Srl","og_description":"Cerchi Microclima-Thermal Comfort? Scopri le caratteristiche di HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT di Senseca Italy Srl","og_url":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/","og_site_name":"Senseca Italy Srl","article_modified_time":"2025-06-05T11:26:04+00:00","og_image":[{"width":1001,"height":1000,"url":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2020\/03\/img_fam_HD32.3TC_tripod-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"2 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/","url":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/","name":"HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT - Microclima-Thermal Comfort - Senseca Italy Srl","isPartOf":{"@id":"https:\/\/environmental.senseca.com\/#website"},"datePublished":"2020-03-24T16:37:40+00:00","dateModified":"2025-06-05T11:26:04+00:00","description":"Cerchi Microclima-Thermal Comfort? Scopri le caratteristiche di HD32.3TC - HD32.3TCA - Microclima Termico PMV-PPD \/ WBGT di Senseca Italy Srl","breadcrumb":{"@id":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/environmental.senseca.com\/it\/prodotto\/hd32-3tc-hd32-3tca-microclima-termico-pmv-ppd-wbgt\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/environmental.senseca.com\/it\/"},{"@type":"ListItem","position":2,"name":"Prodotti","item":"https:\/\/environmental.senseca.com\/products\/"},{"@type":"ListItem","position":3,"name":"HD32.3TC &#8211; HD32.3TCA &#8211; Microclima Termico PMV-PPD \/ WBGT"}]},{"@type":"WebSite","@id":"https:\/\/environmental.senseca.com\/#website","url":"https:\/\/environmental.senseca.com\/","name":"Senseca Italy Srl","description":"Member of GHM GROUP","publisher":{"@id":"https:\/\/environmental.senseca.com\/#organization"},"alternateName":"Senseca","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/environmental.senseca.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/environmental.senseca.com\/#organization","name":"Senseca Italy Srl","url":"https:\/\/environmental.senseca.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/","url":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg","contentUrl":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg","width":1000,"height":1000,"caption":"Senseca Italy Srl"},"image":{"@id":"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/senseca-measurement-solutions\/","https:\/\/www.youtube.com\/@senseca-measurement-solutions"]}]}},"_links":{"self":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product\/12530"}],"collection":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/media\/16285"}],"wp:attachment":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/media?parent=12530"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product_cat?post=12530"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product_tag?post=12530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}