{"id":12841,"date":"2018-12-11T17:20:36","date_gmt":"2018-12-11T17:20:36","guid":{"rendered":"https:\/\/www.deltaohm.com\/product\/hp480-hp481-measurement-of-dew-point-in-compressed-air-systems\/"},"modified":"2021-03-22T11:37:54","modified_gmt":"2021-03-22T11:37:54","slug":"hp480-hp481-misurazione-dew-point-in-condotte","status":"publish","type":"product","link":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/","title":{"rendered":"HP480 &#8211; HP481 &#8211; Misurazione Dew Point in Condotte"},"content":{"rendered":"<p>L\u2019aria compressa viene utilizzata in svariati settori, molti dei quali richiedono aria compressa con un basso livello di umidit\u00e0; ecco pertanto nascere l\u2019esigenza di conoscere il punto di rugiada (DP) del vapore acqueo presente nell\u2019aria compressa che circola nell\u2019impianto.<\/p>\n<p>Le sonde <strong>HP480 e HP481<\/strong> sono progettate appositamente per tale scopo.<\/p>\n<p>L\u2019utilizzo della misura del punto di rugiada per limitare l\u2019umidit\u00e0 negli impianti di distribuzione dell\u2019aria compressa ha molti vantaggi, tra i quali:<\/p>\n<ul>\n<li>prevenire la corrosione delle tubazioni metalliche;<\/li>\n<li>in zone fredde, evitare la formazione di ghiaccio all\u2019interno delle tubazioni con conseguente ostruzione delle tubazioni stesse;<\/li>\n<li>impedire la proliferazione batterica negli impianti per uso medico;<\/li>\n<li>ridurre i costi di manutenzione degli azionamenti pneumatici, preservando la corretta lubrificazione delle parti in movimento;<\/li>\n<li>migliorare la qualit\u00e0 dei prodotti che vengono a contatto con l\u2019aria compressa, per esempio nei processi di essicazione dei granulati.<\/li>\n<\/ul>\n<p><strong>HP480:<\/strong> Sonda per la misura dell&#8217;umidit\u00e0 dell&#8217;aria in tubazioni. Misura umidit\u00e0 relativa e temperatura o Dew Point. Completa di modulo SICRAM. Lunghezza cavo 2 m. Campo di misura: -40\u2026+60 \u00b0C, -40\u2026+60 \u00b0C DP. Tre innesti rapidi 1\/4&#8243;. Pressione di lavoro fino a 16 bar.<\/p>\n<p><strong>HP481:<\/strong> Sonda combinata %UR e temperatura Pt100, con modulo SICRAM. Filettatura G \u00bd\u201d. Cavo 2 m. Filtro in acciaio sinterizzato 15\u03bc AISI 316. Campo d\u2019impiego: -40\u2026+80 \u00b0C, 0\u2026100 %UR. Pressione di lavoro -1\u20268 bar.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sonde intercambiabili per la misurazione di temperatura , umidit\u00e0 e punto di rugiada in condotte.<\/p>\n","protected":false},"featured_media":12842,"template":"","meta":[],"product_cat":[807],"product_tag":[1068,1069,1067,1071,1070],"brands":[{"id":810,"name":"Temperatura","slug":"temperatura"},{"id":764,"name":"Umidit\u00e0","slug":"umidita"}],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>HP480 - HP481 - Misurazione Dew Point in Condotte - Temperatura, Umidit\u00e0 - Senseca Italy Srl<\/title>\n<meta name=\"description\" content=\"Cerchi Temperatura, Umidit\u00e0? Scopri le caratteristiche di HP480 - HP481 - Misurazione Dew Point in Condotte di Senseca Italy Srl\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HP480 - HP481 - Misurazione Dew Point in Condotte - Temperatura, Umidit\u00e0 - Senseca Italy Srl\" \/>\n<meta property=\"og:description\" content=\"Cerchi Temperatura, Umidit\u00e0? Scopri le caratteristiche di HP480 - HP481 - Misurazione Dew Point in Condotte di Senseca Italy Srl\" \/>\n<meta property=\"og:url\" content=\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/\" \/>\n<meta property=\"og:site_name\" content=\"Senseca Italy Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2021-03-22T11:37:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/12\/HP480-dew-point-compressed-air-1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/\",\"url\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/\",\"name\":\"HP480 - HP481 - Misurazione Dew Point in Condotte - Temperatura, Umidit\u00e0 - Senseca Italy Srl\",\"isPartOf\":{\"@id\":\"https:\/\/environmental.senseca.com\/#website\"},\"datePublished\":\"2018-12-11T17:20:36+00:00\",\"dateModified\":\"2021-03-22T11:37:54+00:00\",\"description\":\"Cerchi Temperatura, Umidit\u00e0? Scopri le caratteristiche di HP480 - HP481 - Misurazione Dew Point in Condotte di Senseca Italy Srl\",\"breadcrumb\":{\"@id\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/environmental.senseca.com\/it\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Prodotti\",\"item\":\"https:\/\/environmental.senseca.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HP480 &#8211; HP481 &#8211; Misurazione Dew Point in Condotte\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/environmental.senseca.com\/#website\",\"url\":\"https:\/\/environmental.senseca.com\/\",\"name\":\"Senseca Italy Srl\",\"description\":\"Member of GHM GROUP\",\"publisher\":{\"@id\":\"https:\/\/environmental.senseca.com\/#organization\"},\"alternateName\":\"Senseca\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/environmental.senseca.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/environmental.senseca.com\/#organization\",\"name\":\"Senseca Italy Srl\",\"url\":\"https:\/\/environmental.senseca.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg\",\"contentUrl\":\"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg\",\"width\":1000,\"height\":1000,\"caption\":\"Senseca Italy Srl\"},\"image\":{\"@id\":\"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/senseca-measurement-solutions\/\",\"https:\/\/www.youtube.com\/@senseca-measurement-solutions\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HP480 - HP481 - Misurazione Dew Point in Condotte - Temperatura, Umidit\u00e0 - Senseca Italy Srl","description":"Cerchi Temperatura, Umidit\u00e0? Scopri le caratteristiche di HP480 - HP481 - Misurazione Dew Point in Condotte di Senseca Italy Srl","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/","og_locale":"it_IT","og_type":"article","og_title":"HP480 - HP481 - Misurazione Dew Point in Condotte - Temperatura, Umidit\u00e0 - Senseca Italy Srl","og_description":"Cerchi Temperatura, Umidit\u00e0? Scopri le caratteristiche di HP480 - HP481 - Misurazione Dew Point in Condotte di Senseca Italy Srl","og_url":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/","og_site_name":"Senseca Italy Srl","article_modified_time":"2021-03-22T11:37:54+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/12\/HP480-dew-point-compressed-air-1-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/","url":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/","name":"HP480 - HP481 - Misurazione Dew Point in Condotte - Temperatura, Umidit\u00e0 - Senseca Italy Srl","isPartOf":{"@id":"https:\/\/environmental.senseca.com\/#website"},"datePublished":"2018-12-11T17:20:36+00:00","dateModified":"2021-03-22T11:37:54+00:00","description":"Cerchi Temperatura, Umidit\u00e0? Scopri le caratteristiche di HP480 - HP481 - Misurazione Dew Point in Condotte di Senseca Italy Srl","breadcrumb":{"@id":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/environmental.senseca.com\/it\/prodotto\/hp480-hp481-misurazione-dew-point-in-condotte\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/environmental.senseca.com\/it\/"},{"@type":"ListItem","position":2,"name":"Prodotti","item":"https:\/\/environmental.senseca.com\/products\/"},{"@type":"ListItem","position":3,"name":"HP480 &#8211; HP481 &#8211; Misurazione Dew Point in Condotte"}]},{"@type":"WebSite","@id":"https:\/\/environmental.senseca.com\/#website","url":"https:\/\/environmental.senseca.com\/","name":"Senseca Italy Srl","description":"Member of GHM GROUP","publisher":{"@id":"https:\/\/environmental.senseca.com\/#organization"},"alternateName":"Senseca","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/environmental.senseca.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/environmental.senseca.com\/#organization","name":"Senseca Italy Srl","url":"https:\/\/environmental.senseca.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/","url":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg","contentUrl":"https:\/\/environmental.senseca.com\/wp-content\/uploads\/2018\/07\/logo_prodotti.jpg","width":1000,"height":1000,"caption":"Senseca Italy Srl"},"image":{"@id":"https:\/\/environmental.senseca.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/senseca-measurement-solutions\/","https:\/\/www.youtube.com\/@senseca-measurement-solutions"]}]}},"_links":{"self":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product\/12841"}],"collection":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/media\/12842"}],"wp:attachment":[{"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/media?parent=12841"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product_cat?post=12841"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/environmental.senseca.com\/it\/wp-json\/wp\/v2\/product_tag?post=12841"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}