<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ISO7730 Archives - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-tag/iso7730/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-tag/iso7730/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Mon, 29 Dec 2025 18:02:30 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.8</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>ISO7730 Archives - Senseca</title>
	<link>https://environmental.senseca.com/product-tag/iso7730/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AP3203 &#8211; Omnidirectional Hotwire Probe</title>
		<link>https://environmental.senseca.com/product/ap3203-omnidirectional-hotwire-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/ap3203-omnidirectional-hotwire-probe-2/</guid>

					<description><![CDATA[<p>Omnidirectional hotwire probe with cable for Thermal Comfort measurements. Measuring range: air speed 0.02...5 m/s, temperature 0...+80 °C.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-omnidirectional-hotwire-probe-2/">AP3203 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Omnidirectional hotwire probe for Thermal Comfort Analysis.</p>
<p>Measuring range: air speed 0.02 ÷ 5 m/s, temperature 0&#8230;+80 °C. Probe stem Ø 8 mm, length 230 mm. Cable length 2 metres. Equipped with SICRAM module.</p>
<p>In combination with the data loggers <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a> and <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TCA</a>, the probe is used for calculating the following indices:</p>
<ul>
<li><strong>PMV &#8211; </strong>Predicted Average Rating</li>
<li><strong>PPD &#8211; </strong>Dissatisfied percentage</li>
<li><strong>TU</strong> &#8211; Turbulence</li>
<li><strong>DR &#8211; </strong>Draught rate</li>
</ul>
<p>The probe is also used for calculating <strong>Mean radiant temperature</strong>.</p>
<p>On request air speed ISO 17025 calibration certificate 0.15 – 5 m/s.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-omnidirectional-hotwire-probe-2/">AP3203 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/">HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.<br />
It includes DeltaLog 10 software (with analysis of WBGT, PMV and PPD indices).</p>
<p>The kit is composed of instrument, four AA 1.5 V batteries, instruction manual. The probes and cables have to be ordered separately.</p>
<p>The probes necessary for WBGT measurement are the following:</p>
<ul>
<li>Dry bulb temperature probes TP3207.2.</li>
<li>Globe temperature probe TP3276.2.</li>
<li>Natural ventilation wet bulb temperature probe HP3201.2.</li>
</ul>
<p>The probes necessary for PMV and PPD measurement are the following:</p>
<ul>
<li>Relative humidity and temperature combined probe HP3217.2.</li>
<li>Omnidirectional hotwire probe AP3203.2.</li>
<li>Globe temperature probe TP3276.2.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/">HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AP3203.2 &#8211; Omnidirectional Hotwire Probe</title>
		<link>https://environmental.senseca.com/product/ap3203-2-omnidirectional-hotwire-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/ap3203-2-omnidirectional-hotwire-probe-2/</guid>

					<description><![CDATA[<p>Omnidirectional hotwire probe for Thermal Comfort. Measuring range: air speed 0.02...5 m/s, temperature 0...+80 °C.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-2-omnidirectional-hotwire-probe-2/">AP3203.2 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Omnidirectional hotwire probe for Thermal Comfort Analysis.</p>
<p>Measuring range: air speed 0.02 ÷ 5 m/s, temperature 0 ÷ +80 °C. Probe stem Ø 8 mm, length 230 mm.</p>
<p>Used with the thermal comfort data loggers <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC</a>, the probe is used for calculating the following indices:</p>
<ul>
<li><strong>PMV &#8211; </strong>Predicted Average Rating</li>
<li><strong>PPD &#8211; </strong>Dissatisfied percentage</li>
<li><strong>TU</strong> &#8211; Turbulence</li>
<li><strong>DR &#8211; </strong>Draught rate</li>
</ul>
<p>The probe is also used for calculating <strong>Mean radiant temperature</strong>.</p>
<p>On request air speed ISO 17025 calibration certificate 0.15 – 5 m/s.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-2-omnidirectional-hotwire-probe-2/">AP3203.2 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3TC &#8211; HD32.3TCA &#8211; Thermal Microclimate PMV-PPD / WBGT</title>
		<link>https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 24 Mar 2020 16:37:40 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10777</guid>

					<description><![CDATA[<p>Portable datalogger suitable for indoor air quality and microclimate analysis (Indoor Air Quality, IAQ).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC &#8211; HD32.3TCA &#8211; Thermal Microclimate PMV-PPD / WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate for the measurement of <strong>WBGT, PMV</strong> (mean predicted vote), <strong>PPD</strong> (predicted percentage of dissatisfied), <strong>DR</strong> (draught rate), <strong>TU</strong> (local turbulence intensity), <strong>HI</strong> (heat index), <strong>UTCI</strong> (Universal Thermal Climate Index), <strong>TEP</strong> (perceived equivalent temperature) indices, <strong>CO<sub>2</sub></strong><strong>, PM1.0, PM2.5</strong> and <strong>PM10</strong>. Estimation of <strong>SARS-CoV-2</strong> decay time on surfaces.</p>
<p><strong>HD32.3TC</strong> is the portable version, mostly used in combination with a table stand (small tripod).<br />
<strong>HD32.3TCA</strong> is the version that is being used with a stable tripod, suitable to be used for measurements during a longer period.</p>
<p>Technically the difference is simple: with the <strong>HD32.3TCA the sensors are being connected by a cable</strong> and a black globe of 150mm is used. With the <strong>HD32.3TC</strong> the black globe is 50mm and the<strong> sensors are being connected directly on top of the instrument</strong>.</p>
<p>Both are fully according to the applicable <strong>ISO7730, ISO7726 and ISO7243</strong> regulations.</p>
<ul>
<li><strong>T</strong> dry bulb temperature</li>
<li><strong>T<sub>nw</sub></strong> natural ventilation wet bulb temperature</li>
<li><strong>T<sub>g</sub></strong> globe thermometer temperature</li>
<li><strong>UR</strong> relative humidity</li>
<li><strong>V<sub>a</sub></strong> air speed</li>
<li><strong>CO<sub>2</sub></strong> carbon dioxide</li>
<li><strong>P<sub>atm</sub></strong> atmospheric pressure</li>
<li><strong>PM1.0, PM2.5, PM10</strong> particulate matter</li>
</ul>
<p>A bright and clear touch display allows the calculated values for WBGT, PMV/PPD and TU to be directly visible. The data are immediately available via &#8220;cloud&#8221; application accessible remotely via Wi-Fi connection. The data logger has a large memory capacity for long lasting measurement cycles. Moreover, the rechargeable battery guarantees a working autonomy of at least 24 hours.</p>
<p>Reference standard: <strong>ISO 7726 &#8211;  </strong>Ergonomics of the thermal environment &#8211; Instruments for measuring physical quantities. <strong>ISO 7730 &#8211;  </strong>Ergonomics of the thermal environment &#8211; Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. <strong>ISO 7243 &#8211; </strong>Ergonomics of the thermal environment &#8211; Assessment of heat stress using the WBGT (wet bulb globe temperature) index. <strong>ASHRAE Standard 55 &#8211; </strong>Thermal Environmental Conditions for Human Occupancy. <strong>ASHRAE Standard 62.1-2019 &#8211; </strong>Ventilation for Acceptable Indoor Air Quality. <strong>ASHRAE Standard 62.1-2019 &#8211; </strong>Ventilation for Acceptable Indoor Air Quality.</p>
<p>The HD32.3TC and HD32.3TCA have additional possibilities compared to the HD32.3 and HD32.3A instruments &#8211; sale, repair and maintenance for the old series will of course stay available.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC &#8211; HD32.3TCA &#8211; Thermal Microclimate PMV-PPD / WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
