<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PPD Archives - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-tag/ppd/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-tag/ppd/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Mon, 29 Dec 2025 18:08:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>PPD Archives - Senseca</title>
	<link>https://environmental.senseca.com/product-tag/ppd/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AP3203 &#8211; Omnidirectional Hotwire Probe</title>
		<link>https://environmental.senseca.com/product/ap3203-omnidirectional-hotwire-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/ap3203-omnidirectional-hotwire-probe-2/</guid>

					<description><![CDATA[<p>Omnidirectional hotwire probe with cable for Thermal Comfort measurements. Measuring range: air speed 0.02...5 m/s, temperature 0...+80 °C.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-omnidirectional-hotwire-probe-2/">AP3203 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Omnidirectional hotwire probe for Thermal Comfort Analysis.</p>
<p>Measuring range: air speed 0.02 ÷ 5 m/s, temperature 0&#8230;+80 °C. Probe stem Ø 8 mm, length 230 mm. Cable length 2 metres. Equipped with SICRAM module.</p>
<p>In combination with the data loggers <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a> and <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TCA</a>, the probe is used for calculating the following indices:</p>
<ul>
<li><strong>PMV &#8211; </strong>Predicted Average Rating</li>
<li><strong>PPD &#8211; </strong>Dissatisfied percentage</li>
<li><strong>TU</strong> &#8211; Turbulence</li>
<li><strong>DR &#8211; </strong>Draught rate</li>
</ul>
<p>The probe is also used for calculating <strong>Mean radiant temperature</strong>.</p>
<p>On request air speed ISO 17025 calibration certificate 0.15 – 5 m/s.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-omnidirectional-hotwire-probe-2/">AP3203 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HP3217DM &#8211; Double Probe for Thermal Comfort</title>
		<link>https://environmental.senseca.com/product/hp3217dm-double-probe-for-thermal-comfort/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hp3217dm-double-probe-for-thermal-comfort/</guid>

					<description><![CDATA[<p>Double natural ventilation wet bulb probe and temperature probe (dry bulb).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3217dm-double-probe-for-thermal-comfort/">HP3217DM &#8211; Double Probe for Thermal Comfort</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Double natural ventilation wet bulb probe and temperature probe (dry bulb) to be used with <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a> Thermal Comfrot multifuction data logger.</p>
<p>Probe stem Ø 14 mm, length 110 mm. Cable length 2 metres. Equipped with double SICRAM module, spare cotton wick and 50 cc distilled water.</p>
<p>Measuring range +4 °C…+80 °C.</p>
<p>On request 2 temperature ISO 17025 certificates, one for each probe, at 4 fixed points (VACCREDIA-U9).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3217dm-double-probe-for-thermal-comfort/">HP3217DM &#8211; Double Probe for Thermal Comfort</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.2 &#8211; WBGT Index Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-2-wbgt-index-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT index in Hot Environments</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement-2/">HD32.2 &#8211; WBGT Index Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD32.2 is a thermal microclimate data logger to measure <strong>WBGT (Wet Bulb Globe thermometer temperature)</strong> Index in Hot Environments according to ISO 7726 and ISO 7243.</p>
<p>The instrument is provided with three inputs for probes with SICRAM module: the probes have an electric circuit that communicates with the instrument; the sensor calibration data are saved in its permanent memory. All the SICRAM probes can be inserted in one of the inputs: they are automatically recognized when you switch the instrument on.<br />
The main features of the instrument are:</p>
<ul>
<li><strong>Logging</strong>: acquisition and memorization of data inside the instrument. Memory capacity: 64 different logging sections, with the possibility to set the acquisition interval of the samples. You can set the duration of the memorization and, with auto-start function; it’s possible to set the starting and finishing date and the hour of data memorization.</li>
<li>The measurement unit of the temperature visualized sizes: °C, °F, °K.</li>
<li>The system date and hour.</li>
<li>The visualization of the maximum, minimum and medium statistic parameters and their cancellation.</li>
<li>The transfer speed of the data through the serial port RS232.</li>
</ul>
<p>HD32.2 instrument can contemporarily detect the following sizes:</p>
<ul>
<li><strong>Globe thermometer temperature Tg.</strong></li>
<li><strong>Wet bulb with natural ventilation temperature Tn.</strong></li>
<li><strong>Ambient temperature T.</strong></li>
</ul>
<p>On the basis of the detected measurements, HD32.2 can calculate:</p>
<ul>
<li> <strong>WBGT(in) index</strong> (Wet Bulb Glob Temperature: wet bulb and globe thermometer temperature) in presence or absence of solar irradiation.</li>
<li> <strong>WBGT(out) index</strong> (Wet Bulb Glob Temperature: wet bulb and globe thermometer temperature) in presence of solar irradiation.</li>
</ul>
<p>These probes are requested for the WBGT measurement:</p>
<ul>
<li>Dry bulb temperature probe <a href="https://environmental.senseca.com/product/tp3207-2-pt100-sensor-temperature-probe/">TP3207.2</a>.</li>
<li>Globe temperature probe <a href="https://environmental.senseca.com/product/tp3276-globe-temperature-probe-2/">TP3276.2</a>.</li>
<li>Natural ventilated wet bulb temperature probe <a href="https://environmental.senseca.com/product/hp3201-2-natural-ventilation-wet-bulb-probe/">HP3201.2</a>.</li>
</ul>
<p>HD32.2 is the portable version, mostly used in combination with a table stand (small tripod). For measurements during a longer period we suggest the version with a stable tripod <a href="https://environmental.senseca.com/product/hd32-2a-wbgt-index-measurement/">HD32.3A</a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement-2/">HD32.2 &#8211; WBGT Index Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3276.2 &#8211; Globe Temperature Probe</title>
		<link>https://environmental.senseca.com/product/tp3276-2-globe-temperature-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3276-2-globe-temperature-probe/</guid>

					<description><![CDATA[<p>Globe temperature probe, Pt100 sensor globe Ø 50 mm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3276-2-globe-temperature-probe/">TP3276.2 &#8211; Globe Temperature Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Globe temperature probe with Pt100 sensor, globe Ø 50 mm.</p>
<p>Measuring range -30 °C…+120 °C.</p>
<p>Stem Ø 8 mm, length 170 mm. Complete with SICRAM module.</p>
<p>The probe is used for <strong>measuring WBGT and PMV</strong> with the thermal microclimate data logger HD32.2 and HD32.3TC.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3276-2-globe-temperature-probe/">TP3276.2 &#8211; Globe Temperature Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/">HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.<br />
It includes DeltaLog 10 software (with analysis of WBGT, PMV and PPD indices).</p>
<p>The kit is composed of instrument, four AA 1.5 V batteries, instruction manual. The probes and cables have to be ordered separately.</p>
<p>The probes necessary for WBGT measurement are the following:</p>
<ul>
<li>Dry bulb temperature probes TP3207.2.</li>
<li>Globe temperature probe TP3276.2.</li>
<li>Natural ventilation wet bulb temperature probe HP3201.2.</li>
</ul>
<p>The probes necessary for PMV and PPD measurement are the following:</p>
<ul>
<li>Relative humidity and temperature combined probe HP3217.2.</li>
<li>Omnidirectional hotwire probe AP3203.2.</li>
<li>Globe temperature probe TP3276.2.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/">HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3A &#8211; Data Logger for WBGT, PMW, PPD Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/">HD32.3A &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.<br />
It includes DeltaLog 10 software (with analysis of WBGT, PMV and PPD indices).</p>
<p>The kit is composed of instrument, four AA 1.5 V batteries, instruction manual. The probes and cables have to be ordered separately.</p>
<p>The probes necessary for WBGT measurement are the following:</p>
<ul>
<li>Dry bulb temperature probes TP3207.</li>
<li>Globe temperature probe TP3275.</li>
<li>Natural ventilation wet bulb temperature probe HP3201 or TP3204S.</li>
</ul>
<p>The probes necessary for PMV and PPD measurement are the following:</p>
<ul>
<li>Relative humidity and temperature combined probe HP3217R.</li>
<li>Omnidirectional hotwire probe AP3203.</li>
<li>Globe temperature probe TP3275.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/">HD32.3A &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AP3203.2 &#8211; Omnidirectional Hotwire Probe</title>
		<link>https://environmental.senseca.com/product/ap3203-2-omnidirectional-hotwire-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/ap3203-2-omnidirectional-hotwire-probe-2/</guid>

					<description><![CDATA[<p>Omnidirectional hotwire probe for Thermal Comfort. Measuring range: air speed 0.02...5 m/s, temperature 0...+80 °C.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-2-omnidirectional-hotwire-probe-2/">AP3203.2 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Omnidirectional hotwire probe for Thermal Comfort Analysis.</p>
<p>Measuring range: air speed 0.02 ÷ 5 m/s, temperature 0 ÷ +80 °C. Probe stem Ø 8 mm, length 230 mm.</p>
<p>Used with the thermal comfort data loggers <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC</a>, the probe is used for calculating the following indices:</p>
<ul>
<li><strong>PMV &#8211; </strong>Predicted Average Rating</li>
<li><strong>PPD &#8211; </strong>Dissatisfied percentage</li>
<li><strong>TU</strong> &#8211; Turbulence</li>
<li><strong>DR &#8211; </strong>Draught rate</li>
</ul>
<p>The probe is also used for calculating <strong>Mean radiant temperature</strong>.</p>
<p>On request air speed ISO 17025 calibration certificate 0.15 – 5 m/s.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/ap3203-2-omnidirectional-hotwire-probe-2/">AP3203.2 &#8211; Omnidirectional Hotwire Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP876.I &#8211; Globe-Thermometer &#8211; PMV PPD WBGT</title>
		<link>https://environmental.senseca.com/product/tp876-i-globe-thermometer-pmv-ppd-wbgt-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp876-i-globe-thermometer-pmv-ppd-wbgt-2/</guid>

					<description><![CDATA[<p>Globe thermometer Ø 50 mm, Pt100 sensor. With handle.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp876-i-globe-thermometer-pmv-ppd-wbgt-2/">TP876.I &#8211; Globe-Thermometer &#8211; PMV PPD WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Globe-thermometer</strong> probe for measurement of radiant heat with ∅ 50mm. <strong>Accuracy according to ISO 7243 ISO 7726</strong>.</p>
<p>PMV PPD measurements and WBGT measurements.</p>
<p>Pt100 sensor, 4-wire cable lenght 2 m. Measuring range -30&#8230;+120 °C.</p>
<p>With handle. Supplied with SICRAM module.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp876-i-globe-thermometer-pmv-ppd-wbgt-2/">TP876.I &#8211; Globe-Thermometer &#8211; PMV PPD WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3TC &#8211; HD32.3TCA &#8211; Thermal Microclimate PMV-PPD / WBGT</title>
		<link>https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 24 Mar 2020 16:37:40 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10777</guid>

					<description><![CDATA[<p>Portable datalogger suitable for indoor air quality and microclimate analysis (Indoor Air Quality, IAQ).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC &#8211; HD32.3TCA &#8211; Thermal Microclimate PMV-PPD / WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate for the measurement of <strong>WBGT, PMV</strong> (mean predicted vote), <strong>PPD</strong> (predicted percentage of dissatisfied), <strong>DR</strong> (draught rate), <strong>TU</strong> (local turbulence intensity), <strong>HI</strong> (heat index), <strong>UTCI</strong> (Universal Thermal Climate Index), <strong>TEP</strong> (perceived equivalent temperature) indices, <strong>CO<sub>2</sub></strong><strong>, PM1.0, PM2.5</strong> and <strong>PM10</strong>. Estimation of <strong>SARS-CoV-2</strong> decay time on surfaces.</p>
<p><strong>HD32.3TC</strong> is the portable version, mostly used in combination with a table stand (small tripod).<br />
<strong>HD32.3TCA</strong> is the version that is being used with a stable tripod, suitable to be used for measurements during a longer period.</p>
<p>Technically the difference is simple: with the <strong>HD32.3TCA the sensors are being connected by a cable</strong> and a black globe of 150mm is used. With the <strong>HD32.3TC</strong> the black globe is 50mm and the<strong> sensors are being connected directly on top of the instrument</strong>.</p>
<p>Both are fully according to the applicable <strong>ISO7730, ISO7726 and ISO7243</strong> regulations.</p>
<ul>
<li><strong>T</strong> dry bulb temperature</li>
<li><strong>T<sub>nw</sub></strong> natural ventilation wet bulb temperature</li>
<li><strong>T<sub>g</sub></strong> globe thermometer temperature</li>
<li><strong>UR</strong> relative humidity</li>
<li><strong>V<sub>a</sub></strong> air speed</li>
<li><strong>CO<sub>2</sub></strong> carbon dioxide</li>
<li><strong>P<sub>atm</sub></strong> atmospheric pressure</li>
<li><strong>PM1.0, PM2.5, PM10</strong> particulate matter</li>
</ul>
<p>A bright and clear touch display allows the calculated values for WBGT, PMV/PPD and TU to be directly visible. The data are immediately available via &#8220;cloud&#8221; application accessible remotely via Wi-Fi connection. The data logger has a large memory capacity for long lasting measurement cycles. Moreover, the rechargeable battery guarantees a working autonomy of at least 24 hours.</p>
<p>Reference standard: <strong>ISO 7726 &#8211;  </strong>Ergonomics of the thermal environment &#8211; Instruments for measuring physical quantities. <strong>ISO 7730 &#8211;  </strong>Ergonomics of the thermal environment &#8211; Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. <strong>ISO 7243 &#8211; </strong>Ergonomics of the thermal environment &#8211; Assessment of heat stress using the WBGT (wet bulb globe temperature) index. <strong>ASHRAE Standard 55 &#8211; </strong>Thermal Environmental Conditions for Human Occupancy. <strong>ASHRAE Standard 62.1-2019 &#8211; </strong>Ventilation for Acceptable Indoor Air Quality. <strong>ASHRAE Standard 62.1-2019 &#8211; </strong>Ventilation for Acceptable Indoor Air Quality.</p>
<p>The HD32.3TC and HD32.3TCA have additional possibilities compared to the HD32.3 and HD32.3A instruments &#8211; sale, repair and maintenance for the old series will of course stay available.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC &#8211; HD32.3TCA &#8211; Thermal Microclimate PMV-PPD / WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
