<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UVB Archives - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-tag/uvb/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-tag/uvb/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Mon, 31 May 2021 14:54:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>UVB Archives - Senseca</title>
	<link>https://environmental.senseca.com/product-tag/uvb/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LP471UVA &#8211; UVA Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471uva-uva-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uva-uva-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the UVA spectral range 315nm...400nm, peak at 360nm, quartz diffuser for cosine correction</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uva-uva-irradiance-probe-2/">LP471UVA &#8211; UVA Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the <strong>UVA</strong> spectral range 315 nm…400 nm, peak at 360 nm, quartz diffuser for cosine correction. For non-destructive testing ISO 3059:2001, EN 571-1, ASTM E1417.</p>
<p>Measuring range: 1 mW/m² … 2000 W/m².</p>
<p>Cable length 2 m.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uva-uva-irradiance-probe-2/">LP471UVA &#8211; UVA Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471UVB &#8211; UVB Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471uvb-uvb-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uvb-uvb-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the UVB spectral range 280nm...315nm, peak at 305nm, quartz diffuser for cosine correction</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvb-uvb-irradiance-probe-2/">LP471UVB &#8211; UVB Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the UVB spectral range 280 nm…315 nm, peak at 305 nm, quartz diffuser for cosine correction.</p>
<p>Measuring range: 1 mW/m² … 2000 W/m².</p>
<p>Cable length 2 m.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvb-uvb-irradiance-probe-2/">LP471UVB &#8211; UVB Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471UVC &#8211; UVC Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471uvc-uvc-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uvc-uvc-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the UVC spectral range 220 nm...280 nm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvc-uvc-irradiance-probe-2/">LP471UVC &#8211; UVC Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the <strong>UVC</strong> spectral range 220 nm…280 nm, peak at 260 nm, quartz diffuser for cosine correction.</p>
<p>Measuring range: 1 mW/m² … 2000 W/m².</p>
<p>Cable length 2 m.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvc-uvc-irradiance-probe-2/">LP471UVC &#8211; UVC Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPUVB01 &#8211; Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lpuvb01-irradiance-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 12 Dec 2018 13:08:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=9783</guid>

					<description><![CDATA[<p>Probe for measuring irradiance in the UVB (280 nm ...315 nm) spectral range</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuvb01-irradiance-probe/">LPUVB01 &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>LPUVB01</strong> probe measures irradiance (W/m<sup>2</sup>) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m<sup>2</sup>) in the UVB (280 nm &#8230;315 nm) spectral range.</p>
<p>Thanks to a new type of photodiode, LPUVB01 is blind to visible and infrared light. Probe calibration is carried out by using a 313 nm line of a Xe-Hg lamp, filtered through a special interferential filter.</p>
<p>Measurement is carried out by comparison with the primary standards, assigned to <a href="https://environmental.senseca.com/calibrations/light/">Senseca Metrological Laboratory.</a></p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuvb01-irradiance-probe/">LPUVB01 &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>