<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>WBGT Archives - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-tag/wbgt/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-tag/wbgt/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Mon, 29 Dec 2025 18:08:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>WBGT Archives - Senseca</title>
	<link>https://environmental.senseca.com/product-tag/wbgt/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TP3207TR &#8211; Radiant Temperature Probe</title>
		<link>https://environmental.senseca.com/product/tp3207tr-radiant-temperature-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3207tr-radiant-temperature-probe-2/</guid>

					<description><![CDATA[<p>Probe for radiant temperature and evaluation of dissatisfied people due to radiant asymmetry.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3207tr-radiant-temperature-probe-2/">TP3207TR &#8211; Radiant Temperature Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Probe for measuring <strong>radiant temperature</strong>.</p>
<p>Probe stem Ø 16 mm, length 250 mm. Cable length 2 metres. Equipped with SICRAM module.</p>
<p>Measuring range 0 °C…+60 °C.</p>
<p>The probe is used in combination with the thermal microclimate data logger HD32.1 for the evaluation of dissatisfied people due to radiant asymmetry.</p>
<p>On request, LPNET07 ISO calibration report (VCERT-L26).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3207tr-radiant-temperature-probe-2/">TP3207TR &#8211; Radiant Temperature Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HP3201 &#8211; Natural Ventilation Wet Bulb Probe</title>
		<link>https://environmental.senseca.com/product/hp3201-natural-ventilation-wet-bulb-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hp3201-natural-ventilation-wet-bulb-probe-2/</guid>

					<description><![CDATA[<p>Natural ventilation wet bulb probe with cable for WBGT measurement. Pt100 sensor.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3201-natural-ventilation-wet-bulb-probe-2/">HP3201 &#8211; Natural Ventilation Wet Bulb Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Natural ventilation wet bulb probe. Pt100 sensor. Probe stem Ø 14 mm, length 110 mm. Cable length 2 metres.</p>
<p>Equipped with SICRAM module, two spare cotton wicks and 50 cc distilled water.</p>
<p>Measuring range +4 °C…+80 °C.</p>
<p>Used for <strong>measuring WBGT </strong>with the data loggers <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a>, <a href="https://environmental.senseca.com/product/hd32-2a-wbgt-index-measurement/">HD32.2A</a> and <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TCA</a>.</p>
<p>On request, 4 fixed points temperature ISO 17025 certificate (VACCREDIA-U9).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3201-natural-ventilation-wet-bulb-probe-2/">HP3201 &#8211; Natural Ventilation Wet Bulb Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HP3217DM &#8211; Double Probe for Thermal Comfort</title>
		<link>https://environmental.senseca.com/product/hp3217dm-double-probe-for-thermal-comfort/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hp3217dm-double-probe-for-thermal-comfort/</guid>

					<description><![CDATA[<p>Double natural ventilation wet bulb probe and temperature probe (dry bulb).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3217dm-double-probe-for-thermal-comfort/">HP3217DM &#8211; Double Probe for Thermal Comfort</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Double natural ventilation wet bulb probe and temperature probe (dry bulb) to be used with <a href="https://environmental.senseca.com/product/hd32-1-thermal-microclimate-data-logger/">HD32.1</a> Thermal Comfrot multifuction data logger.</p>
<p>Probe stem Ø 14 mm, length 110 mm. Cable length 2 metres. Equipped with double SICRAM module, spare cotton wick and 50 cc distilled water.</p>
<p>Measuring range +4 °C…+80 °C.</p>
<p>On request 2 temperature ISO 17025 certificates, one for each probe, at 4 fixed points (VACCREDIA-U9).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3217dm-double-probe-for-thermal-comfort/">HP3217DM &#8211; Double Probe for Thermal Comfort</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.2 &#8211; WBGT Index Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-2-wbgt-index-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT index in Hot Environments</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement-2/">HD32.2 &#8211; WBGT Index Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD32.2 is a thermal microclimate data logger to measure <strong>WBGT (Wet Bulb Globe thermometer temperature)</strong> Index in Hot Environments according to ISO 7726 and ISO 7243.</p>
<p>The instrument is provided with three inputs for probes with SICRAM module: the probes have an electric circuit that communicates with the instrument; the sensor calibration data are saved in its permanent memory. All the SICRAM probes can be inserted in one of the inputs: they are automatically recognized when you switch the instrument on.<br />
The main features of the instrument are:</p>
<ul>
<li><strong>Logging</strong>: acquisition and memorization of data inside the instrument. Memory capacity: 64 different logging sections, with the possibility to set the acquisition interval of the samples. You can set the duration of the memorization and, with auto-start function; it’s possible to set the starting and finishing date and the hour of data memorization.</li>
<li>The measurement unit of the temperature visualized sizes: °C, °F, °K.</li>
<li>The system date and hour.</li>
<li>The visualization of the maximum, minimum and medium statistic parameters and their cancellation.</li>
<li>The transfer speed of the data through the serial port RS232.</li>
</ul>
<p>HD32.2 instrument can contemporarily detect the following sizes:</p>
<ul>
<li><strong>Globe thermometer temperature Tg.</strong></li>
<li><strong>Wet bulb with natural ventilation temperature Tn.</strong></li>
<li><strong>Ambient temperature T.</strong></li>
</ul>
<p>On the basis of the detected measurements, HD32.2 can calculate:</p>
<ul>
<li> <strong>WBGT(in) index</strong> (Wet Bulb Glob Temperature: wet bulb and globe thermometer temperature) in presence or absence of solar irradiation.</li>
<li> <strong>WBGT(out) index</strong> (Wet Bulb Glob Temperature: wet bulb and globe thermometer temperature) in presence of solar irradiation.</li>
</ul>
<p>These probes are requested for the WBGT measurement:</p>
<ul>
<li>Dry bulb temperature probe <a href="https://environmental.senseca.com/product/tp3207-2-pt100-sensor-temperature-probe/">TP3207.2</a>.</li>
<li>Globe temperature probe <a href="https://environmental.senseca.com/product/tp3276-globe-temperature-probe-2/">TP3276.2</a>.</li>
<li>Natural ventilated wet bulb temperature probe <a href="https://environmental.senseca.com/product/hp3201-2-natural-ventilation-wet-bulb-probe/">HP3201.2</a>.</li>
</ul>
<p>HD32.2 is the portable version, mostly used in combination with a table stand (small tripod). For measurements during a longer period we suggest the version with a stable tripod <a href="https://environmental.senseca.com/product/hd32-2a-wbgt-index-measurement/">HD32.3A</a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement-2/">HD32.2 &#8211; WBGT Index Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.2A &#8211; WBGT Index Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-2a-wbgt-index-measurement/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-2a-wbgt-index-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT index in Hot Environments</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-2a-wbgt-index-measurement/">HD32.2A &#8211; WBGT Index Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HD32.2A is a thermal microclimate data logger to measure <strong>WBGT (Wet Bulb Globe thermometer temperature)</strong> Index in Hot Environments according to ISO 7726 and ISO 7243.</p>
<p>Once mounted on its tripod VTRAP32.2A.3A , the instrument is suitable for long period measurements. It is provided with three inputs for probes with cables to be fixed on the dedicated holder HD32.2.7.1. The probes are provided with SICRAM module: they have an electric circuit that communicates with the instrument. The sensor calibration data are saved in its permanent memory. All the SICRAM probes can be inserted in one of the inputs: they are automatically recognized when you switch the instrument on.</p>
<p>The main features of the instrument are:</p>
<ul>
<li><strong>Logging</strong>: acquisition and memorization of data inside the instrument. Memory capacity: 64 different logging sections, with the possibility to set the acquisition interval of the samples. You can set the duration of the memorization and, with auto-start function; it’s possible to set the starting and finishing date and the hour of data memorization.</li>
<li>The measurement unit of the temperature visualized sizes: °C, °F, °K.</li>
<li>The system date and hour.</li>
<li>The visualization of the maximum, minimum and medium statistic parameters and their cancellation.</li>
<li>The transfer speed of the data through the serial port RS232.</li>
</ul>
<p>HD32.2A instrument can contemporarily detect the following sizes:</p>
<ul>
<li><strong>Globe thermometer temperature Tg.</strong></li>
<li><strong>Wet bulb with natural ventilation temperature Tn.</strong></li>
<li><strong>Ambient temperature T.</strong></li>
</ul>
<p>On the basis of the detected measurements, HD32.2A can calculate:</p>
<ul>
<li> <strong>WBGT(in) index</strong> (Wet Bulb Glob Temperature: wet bulb and globe thermometer temperature) in presence or absence of solar irradiation.</li>
<li> <strong>WBGT(out) index</strong> (Wet Bulb Glob Temperature: wet bulb and globe thermometer temperature) in presence of solar irradiation.</li>
</ul>
<p>With the HD32.2A, following probes are requested for the WBGT measurement:</p>
<ul>
<li>Dry bulb temperature probe <a href="https://environmental.senseca.com/product/tp3207-pt100-sensor-temperature-probe/">TP3207</a>.</li>
<li>Globe temperature probe <a href="https://environmental.senseca.com/product/tp3275-globe-temperature-probe/">TP3275</a>.</li>
<li>Wet bulb temperature probe with natural ventilation <a href="https://environmental.senseca.com/product/hp3201-natural-ventilation-wet-bulb-probe/">HP3201</a> or <a href="https://environmental.senseca.com/product/tp3204s-natural-ventilation-wet-bulb-probe/">TP3204S</a>.</li>
</ul>
<p>A simple portable version is also available. See <a href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement/">HD32.2</a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-2a-wbgt-index-measurement/">HD32.2A &#8211; WBGT Index Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3207.2 &#8211; Dry Bulb Temperature Probe for WBGT</title>
		<link>https://environmental.senseca.com/product/tp3207-2-dry-bulb-temperature-probe-for-wbgt/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3207-2-dry-bulb-temperature-probe-for-wbgt/</guid>

					<description><![CDATA[<p>Dry bulb temperature probe used for calculating the following indices: IREQ,WCI, DLE, RT, PMV, PPD, WBGT, SR and mean radiant temperature. Pt100 sensor.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3207-2-dry-bulb-temperature-probe-for-wbgt/">TP3207.2 &#8211; Dry Bulb Temperature Probe for WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Pt100 sensor temperature probe. Probe stem Ø 14 mm, length 150 mm. Equipped with SICRAM module.</p>
<p>Measuring range -40 °C…+100 °C.</p>
<p>Uncertainty +/- 0.15 °C in the range -30 °C …+100 °C.</p>
<p>Response time 10” at constant temperature.</p>
<p>Used for calculating the following indices: IREQ,WCI, DLE, RT, PMV, PPD, WBGT, SR. Used for calculating Mean radiant temperature.</p>
<p>The probe is suitable to be used with <a href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement/">HD32.2</a> and <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC</a>.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3207-2-dry-bulb-temperature-probe-for-wbgt/">TP3207.2 &#8211; Dry Bulb Temperature Probe for WBGT</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TP3276.2 &#8211; Globe Temperature Probe</title>
		<link>https://environmental.senseca.com/product/tp3276-2-globe-temperature-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/tp3276-2-globe-temperature-probe/</guid>

					<description><![CDATA[<p>Globe temperature probe, Pt100 sensor globe Ø 50 mm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3276-2-globe-temperature-probe/">TP3276.2 &#8211; Globe Temperature Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Globe temperature probe with Pt100 sensor, globe Ø 50 mm.</p>
<p>Measuring range -30 °C…+120 °C.</p>
<p>Stem Ø 8 mm, length 170 mm. Complete with SICRAM module.</p>
<p>The probe is used for <strong>measuring WBGT and PMV</strong> with the thermal microclimate data logger HD32.2 and HD32.3TC.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/tp3276-2-globe-temperature-probe/">TP3276.2 &#8211; Globe Temperature Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HP3201.2 &#8211; Natural Ventilation Wet Bulb Probe</title>
		<link>https://environmental.senseca.com/product/hp3201-2-natural-ventilation-wet-bulb-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hp3201-2-natural-ventilation-wet-bulb-probe-2/</guid>

					<description><![CDATA[<p>Natural ventilation wet bulb probe for WBGT measurement. Pt100 sensor.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3201-2-natural-ventilation-wet-bulb-probe-2/">HP3201.2 &#8211; Natural Ventilation Wet Bulb Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Wet bulb probe with natural ventilation. Pt100 sensor. Probe dimensions: stem Ø 14 mm, length 170 mm. Equipped with SICRAM module, two spare cotton wicks and 50 cc distilled water.</p>
<p>Measuring range: +4 °C&#8230;+80 °C<br />
Accuracy: Class A<br />
Resolution: 0.1°C<br />
Drifting in temperature @20°C: 0.003%/°C<br />
Drifting after 1 year: 0.1°C/year<br />
Connection: 4 wires plus SICRAM module<br />
Connector: 8-pole female DIN45326<br />
Cotton wick length: about 10 cm<br />
Tank capacity: 15 cc<br />
Tank autonomy: 96 hours con RH=50%, t = 23°C<br />
Response time T<sub>95</sub>: 15 minutes</p>
<p>The probe is used with the thermal comfort and WBGT data loggers <a href="https://environmental.senseca.com/product/hd32-2-wbgt-index-measurement/">HD32.2</a> and <a href="https://environmental.senseca.com/product/hd32-3tc-thermal-microclimate-pmv-ppd-wbgt/">HD32.3TC</a> for the WBGT measurement.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hp3201-2-natural-ventilation-wet-bulb-probe-2/">HP3201.2 &#8211; Natural Ventilation Wet Bulb Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3A &#8211; Data Logger for WBGT, PMW, PPD Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/">HD32.3A &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.<br />
It includes DeltaLog 10 software (with analysis of WBGT, PMV and PPD indices).</p>
<p>The kit is composed of instrument, four AA 1.5 V batteries, instruction manual. The probes and cables have to be ordered separately.</p>
<p>The probes necessary for WBGT measurement are the following:</p>
<ul>
<li>Dry bulb temperature probes TP3207.</li>
<li>Globe temperature probe TP3275.</li>
<li>Natural ventilation wet bulb temperature probe HP3201 or TP3204S.</li>
</ul>
<p>The probes necessary for PMV and PPD measurement are the following:</p>
<ul>
<li>Relative humidity and temperature combined probe HP3217R.</li>
<li>Omnidirectional hotwire probe AP3203.</li>
<li>Globe temperature probe TP3275.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3a-wbgt-pmw-ppd-measurement-2/">HD32.3A &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</title>
		<link>https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/</guid>

					<description><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/">HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermal microclimate to measure the WBGT Index, PMV Index (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied). 3 inputs for probes with SICRAM module, graphic display.<br />
It includes DeltaLog 10 software (with analysis of WBGT, PMV and PPD indices).</p>
<p>The kit is composed of instrument, four AA 1.5 V batteries, instruction manual. The probes and cables have to be ordered separately.</p>
<p>The probes necessary for WBGT measurement are the following:</p>
<ul>
<li>Dry bulb temperature probes TP3207.2.</li>
<li>Globe temperature probe TP3276.2.</li>
<li>Natural ventilation wet bulb temperature probe HP3201.2.</li>
</ul>
<p>The probes necessary for PMV and PPD measurement are the following:</p>
<ul>
<li>Relative humidity and temperature combined probe HP3217.2.</li>
<li>Omnidirectional hotwire probe AP3203.2.</li>
<li>Globe temperature probe TP3276.2.</li>
</ul>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-3-wbgt-pmw-ppd-measurement-2/">HD32.3 &#8211; Data Logger for WBGT, PMW, PPD Measurement</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>