<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Data Logger for measuring, testing and control instruments - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-category/data-logger/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-category/data-logger/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Wed, 20 May 2026 15:46:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.8</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>Data Logger for measuring, testing and control instruments - Senseca</title>
	<link>https://environmental.senseca.com/product-category/data-logger/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HD33M-MB.4 &#8211; 4G Data Logger for Remote Monitoring</title>
		<link>https://environmental.senseca.com/product/hd33m-mb-4-4g-data-logger-for-remote-monitoring/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 20 May 2026 15:36:49 +0000</pubDate>
				<guid isPermaLink="false">https://environmental.senseca.com/?post_type=product&#038;p=16744</guid>

					<description><![CDATA[<p>Remote 4G data logger for environmental and industrial monitoring</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd33m-mb-4-4g-data-logger-for-remote-monitoring/">HD33M-MB.4 &#8211; 4G Data Logger for Remote Monitoring</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div data-testid="markdown-response">
<div>
<p id="message">The <strong>HD33[L]M-MB.4</strong> is a robust 4G data logger designed for remote environmental, meteorological and industrial monitoring. It collects data from RS485 Modbus-RTU sensors and transmits measurements via <strong>4G / 3G / GSM / GPRS</strong>, reducing the need for on-site data retrieval.</p>
</div>
</div>
<div data-testid="markdown-response">
<div>It supports multiple measurement parameters such as temperature, humidity, atmospheric pressure, solar radiation, wind speed, wind direction and rainfall, making it suitable for weather stations, environmental monitoring networks and remote field installations.</div>
</div>
<div data-testid="markdown-response">
<div>
<h3>Key Benefits</h3>
</div>
</div>
<div data-testid="markdown-response">
<div>
<ul>
<li>Remote data transmission via <strong>e-mail, FTP or HTTP server</strong></li>
<li><strong>RS485 Modbus-RTU master input</strong> for multi-sensor networks</li>
<li>Rain gauge input with rainfall rate and daily rainfall calculation</li>
<li>Remote configuration and control via <strong>SMS commands</strong> or TCP/IP</li>
<li>Configurable alarm thresholds with notification by SMS or e-mail</li>
<li>Internal memory for up to <strong>424,000 samples</strong></li>
<li>Optional LCD display</li>
<li><strong>IP67 housing</strong> for outdoor installations</li>
<li>Suitable for wall or mast mounting</li>
<li>Compatible with solar-powered systems</li>
</ul>
</div>
</div>
<div data-testid="markdown-response">
<div>
<h3>Typical Applications</h3>
</div>
</div>
<div data-testid="markdown-response">
<div>
<ul>
<li>Environmental monitoring stations</li>
<li>Weather and climate observation</li>
<li>Rainfall and hydrological monitoring</li>
<li>Remote industrial measurement points</li>
<li>Field data acquisition systems</li>
<li>Solar-powered monitoring installations</li>
</ul>
</div>
</div>
<p hidden="">HD33M-MB.2,HD33M-MB.2X,HD33M-MB.2W,HD33LM-MB.2,HD33LM-MB.2X,HD33LM-MB.2W,/p&gt;</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd33m-mb-4-4g-data-logger-for-remote-monitoring/">HD33M-MB.4 &#8211; 4G Data Logger for Remote Monitoring</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MeteoData-4000 series &#8211; Multi-Purpose Data Logger with Global Connectivity</title>
		<link>https://environmental.senseca.com/product/meteodata-4000-series-multi-purpose-data-logger-with-global-connectivity/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 12 Nov 2025 09:42:43 +0000</pubDate>
				<guid isPermaLink="false">https://environmental.senseca.com/?post_type=product&#038;p=16550</guid>

					<description><![CDATA[<p>Advanced data acquisition system with very low power consumption for environmental monitoring networks.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/meteodata-4000-series-multi-purpose-data-logger-with-global-connectivity/">MeteoData-4000 series &#8211; Multi-Purpose Data Logger with Global Connectivity</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong data-start="174" data-end="199">METEODATA-4000 Series</strong> is Senseca’s next-generation <strong data-start="229" data-end="258">environmental data logger</strong> designed for reliable, autonomous operation in demanding outdoor installations. Built as an open platform, it connects to a wide range of <strong data-start="397" data-end="413">COTS sensors</strong> (analogue, pulse and smart digital) and combines <strong data-start="463" data-end="485">onboard processing</strong>, <strong data-start="487" data-end="507">self-diagnostics</strong> and <strong data-start="512" data-end="530">alarm handling</strong> to help ensure high-quality data in real-world conditions.</p>
<h3 data-start="629" data-end="645">Key benefits</h3>
<ul>
<li><strong>Very low power consumption </strong>for long-term autonomous operation<strong>.</strong></li>
<li data-start="788" data-end="944"><strong data-start="788" data-end="822">Universal sensor compatibility</strong> via analogue and digital interfaces (RS-232/RS-485, SDI-12, Modbus and more).</li>
<li><strong>High-capacity I/O resources</strong> designed to support complex monitoring systems.</li>
<li data-start="947" data-end="1096"><strong data-start="947" data-end="984">Embedded data processing &amp; alarms</strong> with up to <strong data-start="996" data-end="1023">32 measurement channels</strong> and <strong data-start="1028" data-end="1055">up to 32 alarm channels</strong>.</li>
<li data-start="1099" data-end="1299"><strong data-start="1099" data-end="1130">Global connectivity options</strong> including cellular, Wi-Fi, Bluetooth Low Energy, Ethernet and satellite interfaces.</li>
<li data-start="1302" data-end="1452"><strong data-start="1302" data-end="1326">Faster commissioning</strong> with drag-and-drop sensor setup via the software ecosystem and online sensor library.</li>
</ul>
<h3 data-start="1454" data-end="1478">Typical applications</h3>
<p>Meteorological and hydrological monitoring, solar resource &amp; PV plant monitoring, road weather (RWIS), air quality monitoring, early warning networks and multi-parameter monitoring projects.</p>
<h3 data-start="1438" data-end="1465">Software &amp; data services</h3>
<p>The <strong>GEO-DataView</strong> software suite for METEODATA-4000 series comprises:</p>
<ul>
<li>a <strong>cloud</strong> platform for simple and secure browser-based data access (Webtrans 4K),</li>
<li>a <strong>desktop</strong> software for the datalogger and sensors management (Teletrans-W4K), and</li>
<li>a <strong>mobile app (iOS and Android)</strong> for direct access to the device (GEO-DataLink).</li>
</ul>
<h3 data-start="1454" data-end="1478"><a href="https://environmental.senseca.com/senseca-geo-platform/">For detailed user guides and software documentation, click <strong data-start="345" data-end="353">here.</strong></a></h3>
<p data-start="1479" data-end="1766"><strong><a href="https://www.geonica.com/en/data-acquisition.php">MTD4000 on Senseca Spain website – click here.</a></strong></p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/meteodata-4000-series-multi-purpose-data-logger-with-global-connectivity/">MeteoData-4000 series &#8211; Multi-Purpose Data Logger with Global Connectivity</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD50R-MB &#8211; Data Logger DIN Rail with Ethernet Connectivity</title>
		<link>https://environmental.senseca.com/product/hd50rmb-din-rail-logger-ethernet-connectivity/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 23 Jul 2024 13:00:31 +0000</pubDate>
				<guid isPermaLink="false">https://environmental.senseca.com/?post_type=product&#038;p=15890</guid>

					<description><![CDATA[<p>Data logger with Master RS485 Modbus-RTU interface for acquiring sensors with RS485 Modbus-RTU output. 35 mm DIN rail installation.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd50rmb-din-rail-logger-ethernet-connectivity/">HD50R-MB &#8211; Data Logger DIN Rail with Ethernet Connectivity</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HD50R-MB data logger monitors various physical quantities across many applications. It connects to sensors <strong>via the RS485 MODBUS-RTU input</strong> to measure temperature, humidity, atmospheric pressure, solar radiation, wind speed and direction (e.g., HD52.3D series anemometers).</p>
<p>A voltage-free contact input allows connection to a rain gauge with a contact output (normally open or closed). It calculates the rainfall rate in mm/h and the daily rainfall quantity.</p>
<p>The data logger supports <strong>Ethernet connections</strong> and can operate <strong>two communication protocols simultaneously: proprietary and Modbus TCP/IP</strong>, managing up to 10 TCP/IP clients. It can send data to an<strong> FTP address, the Cloud, and via email.</strong></p>
<p>Users can set two alarm thresholds for each measured quantity, with acoustic and email notifications for exceeded thresholds. Alarm hysteresis and delay are configurable.</p>
<p>The <strong>HD35AP-S software</strong> configures the data logger, displays real-time measurements, and manages data. HDServer1 software can handle multiple data loggers, automatically detecting and managing them in a network, and entering data into a database. The HD35AP-CFR21 option ensures data protection compliant with FDA 21 CFR part 11.</p>
<p>The data logger is installed on a 35 mm DIN rail and requires a 7…30 Vdc external power supply.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd50rmb-din-rail-logger-ethernet-connectivity/">HD50R-MB &#8211; Data Logger DIN Rail with Ethernet Connectivity</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LR35 Series &#8211; IoT Data Loggers for LoRaWAN Networks</title>
		<link>https://environmental.senseca.com/product/lr35-series-iot-data-loggers-for-lorawan-networks/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Fri, 05 Mar 2021 11:39:04 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=13698</guid>

					<description><![CDATA[<p>Data loggers with LoRaWAN® technology: the perfect fit for situations where Long Range transmission is a need.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lr35-series-iot-data-loggers-for-lorawan-networks/">LR35 Series &#8211; IoT Data Loggers for LoRaWAN Networks</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The data loggers of the <strong>LR35…</strong> series are wireless devices for IoT (Internet of Things) applications that use <strong>LoRaWAN® technology for long distance data transmission.</strong></p>
<p>LoRaWAN® technology uses the unlicensed frequencies of the ISM band (for example EU868, US915, AU915, KR920, AS923, IN865) and allows a<strong> transmission range of several kilometers</strong> depending on the installation position and the urbanization condition of the place where the network infrastructure is located, with<strong> extremely limited energy consumption</strong>, allowing long operation of battery-powered devices.</p>
<p>With the LR35… series, we provides a wide range of loggers with sensors for all general measurement conditions like temperature, humidity, differential pressure, CO<sub>2</sub>, PM.</p>
<p>For outdoor applications, we have specific IP67 loggers with connections to pyranometers, rain gauges and soil moisture.</p>
<p>But also we connect any other third party measurement with LoRa as long as it has a standard output: 4-20mA, 0-10V, Modbus-RTU.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lr35-series-iot-data-loggers-for-lorawan-networks/">LR35 Series &#8211; IoT Data Loggers for LoRaWAN Networks</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.8.16 &#8211; 16 Inputs Temperature Data Logger &#8211; Thermocouples</title>
		<link>https://environmental.senseca.com/product/hd32-8-16-16-inputs-data-logger-for-thermocouples-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-8-16-16-inputs-data-logger-for-thermocouples-2/</guid>

					<description><![CDATA[<p>Rugged data logger with 16 inputs for K, J, T, N, R, S, B and E type thermocouple</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-8-16-16-inputs-data-logger-for-thermocouples-2/">HD32.8.16 &#8211; 16 Inputs Temperature Data Logger &#8211; Thermocouples</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Rugged data logger with <strong>16 input</strong>s <strong>for K, J, T, N, R, S, B and E type thermocouple</strong> with miniature connector temperature probes.</p>
<p>Main features:</p>
<ul>
<li>Unit of measurement °C, °F, °K configurable.</li>
<li>Flash memory organized in 64 sections with a total capacity of 800.000 acquisitions to be divided among all the present inputs. Storage can be managed in two ways:
<ul>
<li>when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),</li>
<li>storage stops when the available memory is full.</li>
</ul>
</li>
<li>Simultaneous display in group of 4.</li>
<li>Maximum, minimum or average of the stored values.</li>
<li>Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.</li>
<li>Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.</li>
<li>Data download: RS232C, 1200&#8230;38400 baud or USB 1.1 &#8211; 2.0.</li>
<li>DeltaLog9 software for data download and processing.</li>
<li>LCD backlit graphic display 128&#215;64 pixel.</li>
<li>Instrument setup through the keyboard; no connection required to the PC.</li>
<li>Security password for keyboard locking.</li>
<li>Power supply: 4 1.5V alkaline C-BABY type batteries, or external power supply 12VDC-1A or by means of the USB port of the PC.</li>
<li>Consumption @6VDC:
<ul>
<li>&lt;60μA when the instrument is off</li>
<li>&lt;60μA in sleep mode with 8 probes connected</li>
<li>&lt;40mA with all probes connected</li>
</ul>
</li>
</ul>
<p>Use of data loggers HD32.8.8 and HD32.8.16: in field for measurement campaigns on complex systems with many measurement points, testing facilities, in pharmaceutical and food sectors, ovens mapping, air conditioning centrals etc.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-8-16-16-inputs-data-logger-for-thermocouples-2/">HD32.8.16 &#8211; 16 Inputs Temperature Data Logger &#8211; Thermocouples</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.7 &#8211; 8 Inputs Temperature Data Logger &#8211; Pt100</title>
		<link>https://environmental.senseca.com/product/hd32-7-8-inputs-data-logger-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-7-8-inputs-data-logger-2/</guid>

					<description><![CDATA[<p>8 Inputs temperature datalogger for Pt100 sensor probes</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-7-8-inputs-data-logger-2/">HD32.7 &#8211; 8 Inputs Temperature Data Logger &#8211; Pt100</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The instrument HD32.7 is a robust <strong>8 inputs data logger for Pt100 sensor temperature probes</strong>. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000.</p>
<p>Main features:</p>
<ul>
<li>Unit of measurement °C, °F, °K configurable.</li>
<li>Flash memory organized in 64 sections with a total capacity of 96.000 acquisitions for each one of the 8 inputs. Storage can be managed in two ways:
<ul>
<li>when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),</li>
<li>storage stops when the available memory is full.</li>
</ul>
</li>
<li>Simultaneous display of the 8 inputs.</li>
<li>Maximum, minimum or average of the stored values.</li>
<li>Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.</li>
<li>Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.</li>
<li>Data download: RS232C, 1200&#8230;38400 baud or USB 1.1 &#8211; 2.0.</li>
<li>DeltaLog9 software for data download and processing.</li>
<li>LCD backlit graphic display 128&#215;64 pixel.</li>
<li>Instrument setup through the keyboard; no connection required to the PC.</li>
<li>Security password for keyboard locking.</li>
<li>Power supply: 4 1.5V alkaline C-BABY type batteries or external power supply 12VDC-1A.</li>
<li>Consumption @6VDC:
<ul>
<li>&lt;60μA when the instrument is off</li>
<li>&lt;60μA in sleep mode with 8 probes connected</li>
<li>&lt;40mA during data logging with 8 probes connected</li>
</ul>
</li>
</ul>
<p>Use of the HD32.7 data logger: in the field for machine or equipment measurements, plant or machine testing, production check, oven mapping.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-7-8-inputs-data-logger-2/">HD32.7 &#8211; 8 Inputs Temperature Data Logger &#8211; Pt100</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32.8.8 &#8211; 8 Inputs Temperature Data Logger &#8211; Thermocouples</title>
		<link>https://environmental.senseca.com/product/hd32-8-8-8-inputs-data-logger-for-thermocouples-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32-8-8-8-inputs-data-logger-for-thermocouples-2/</guid>

					<description><![CDATA[<p>Rugged data logger with 8 inputs for K, J, T, N, R, S, B and E type thermocouples.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-8-8-8-inputs-data-logger-for-thermocouples-2/">HD32.8.8 &#8211; 8 Inputs Temperature Data Logger &#8211; Thermocouples</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Rugged data logger with <strong>8 input</strong>s <strong>for K, J, T, N, R, S, B and E type thermocouple</strong> with miniature connector temperature probes.</p>
<p>Main features:</p>
<ul>
<li>Unit of measurement °C, °F, °K configurable.</li>
<li>Flash memory organized in 64 sections with a total capacity of 800.000 acquisitions to be divided among all the present inputs. Storage can be managed in two ways:
<ul>
<li>when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),</li>
<li>storage stops when the available memory is full.</li>
</ul>
</li>
<li>Simultaneous display in group of 4.</li>
<li>Maximum, minimum or average of the stored values.</li>
<li>Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.</li>
<li>Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.</li>
<li>Data download: RS232C, 1200&#8230;38400 baud or USB 1.1 &#8211; 2.0.</li>
<li>DeltaLog9 software for data download and processing.</li>
<li>LCD backlit graphic display 128&#215;64 pixel.</li>
<li>Instrument setup through the keyboard; no connection required to the PC.</li>
<li>Security password for keyboard locking.</li>
<li>Power supply: 4 1.5V alkaline C-BABY type batteries, or external power supply 12VDC-1A or by means of the USB port of the PC.</li>
<li>Consumption @6VDC:
<ul>
<li>&lt;60μA when the instrument is off</li>
<li>&lt;60μA in sleep mode with 8 probes connected</li>
<li>&lt;40mA with all probes connected</li>
</ul>
</li>
</ul>
<p>Use of data loggers HD32.8.8 and HD32.8.16: in field for measurement campaigns on complex systems with many measurement points, testing facilities, in pharmaceutical and food sectors, ovens mapping, air conditioning centrals etc.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32-8-8-8-inputs-data-logger-for-thermocouples-2/">HD32.8.8 &#8211; 8 Inputs Temperature Data Logger &#8211; Thermocouples</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD33M.2 &#8211; GSM/GPRS Data Loggers for Weather Stations</title>
		<link>https://environmental.senseca.com/product/hd33m-2-gsm-gprs-data-loggers-for-weather-stations/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 14 Sep 2020 15:25:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd33m-2-gsm-gprs-data-loggers-for-weather-stations/</guid>

					<description><![CDATA[<p>GSM/GPRS data loggers for weather stations with inputs for dedicated Senseca sensors and cup anemometer</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd33m-2-gsm-gprs-data-loggers-for-weather-stations/">HD33M.2 &#8211; GSM/GPRS Data Loggers for Weather Stations</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://environmental.senseca.com/wp-content/uploads/document/DeltaOHM_HD33_Meteo_Loggers_Flyer_ENG.pdf" target="_blank" rel="noopener noreferrer"><img decoding="async" fetchpriority="high" class="alignnone size-full wp-image-10838" src="https://environmental.senseca.com/wp-content/uploads/2018/10/HD33all.jpg" alt="" width="836" height="258" srcset="https://environmental.senseca.com/wp-content/uploads/2018/10/HD33all.jpg 836w, https://environmental.senseca.com/wp-content/uploads/2018/10/HD33all-300x93.jpg 300w, https://environmental.senseca.com/wp-content/uploads/2018/10/HD33all-768x237.jpg 768w, https://environmental.senseca.com/wp-content/uploads/2018/10/HD33all-600x185.jpg 600w" sizes="(max-width: 836px) 100vw, 836px" /></a></p>
<p><em>Please click on the picture to see an overview of the compact meteorological loggers to assist you in finding the best possible solution</em></p>
<p>The <strong>HD33M.2</strong> data logger has an integrated GSM/GPRS module. It has 5 inputs: easy to use for monitoring (and/or) temperature, humidity, solar radiation, rainfall quantity, wind speed and direction (with cup-anemometer). Optional atmospheric pressure can be integrated in the unit. The instrument can simply be integrated with any FTP or Cloud solution.</p>
<p>Data logger:</p>
<ul>
<li>Datalogging of temperature, relative humidity, dew point temperature, atmospheric pressure, solar radiation, rainfall amount, wind speed and direction</li>
<li>Available in two versions: with input for standard RS485 MODBUS-RTU sensors or with inputs for dedicated Senseca sensors</li>
<li>GSM/GPRS module for remote monitoring</li>
<li>Data sending via email, FTP and to an HTTP server (e.g. Senseca Cloud)</li>
<li>PC software for configuration, monitoring and downloading of data to a database</li>
<li>Software option available for compliance with FDA 21 CFR part 11 recommendations</li>
<li>Alarm notification via e-mail and SMS when configurable measurement thresholds are exceeded</li>
<li>IP 67 waterproof housing</li>
<li>Optional custom LCD display (H<strong>D33LM.2</strong>)</li>
<li>Can be powered by mains or photovoltaic panel (with optional external power supply unit)</li>
<li>Atmospheric pressure option (HD33M4b.2 or HD33LM4b.2)</li>
</ul>
<p hidden="">HD33M.2, HD33LM.2, HD33M.2X, HD33M.2W, HD33LM.2X, HD33LM.2W, HD33M4b.2, HD33M4b.2X, HD33M4b.2W, HD33LM4b.2, HD33LM4b.2X, HD33LM4b.2W</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd33m-2-gsm-gprs-data-loggers-for-weather-stations/">HD33M.2 &#8211; GSM/GPRS Data Loggers for Weather Stations</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD32MT.1 &#8211; Programmable Data Logger</title>
		<link>https://environmental.senseca.com/product/hd32mt-1-programmable-data-logger/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 14 Sep 2020 15:25:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd32mt-1-programmable-data-logger/</guid>

					<description><![CDATA[<p>Programmable datalogger able to capture and store the values measured by a series of sensors connected to its inputs. 8 analoge input, 8 digitale input, 2 puls input, potential free contacts, alarming. Programmable through software. RS485, RS232.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32mt-1-programmable-data-logger/">HD32MT.1 &#8211; Programmable Data Logger</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HD32MT.1 is a <strong>data logger</strong> capable of capturing and logging the values measured by a series of sensors connected to its inputs.</p>
<p>The data logger is <strong>completely programmable by the user</strong> and is therefore very versatile.</p>
<p>The supplied <a href="https://environmental.senseca.com/support/software/hd32mtlogger/">HD32MTLogger application software</a> allows simple and intuitive programming by using graphic interfaces, without the need of learning any programming language, thus minimizing the time needed to make the system operational.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd32mt-1-programmable-data-logger/">HD32MT.1 &#8211; Programmable Data Logger</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD50CR &#8211; Clean Room Logger Transmitter</title>
		<link>https://environmental.senseca.com/product/hd50cr-clean-room-logger-transmitter/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 31 Mar 2020 08:39:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10812</guid>

					<description><![CDATA[<p>Relative or differential low pressure transmitter and data logger designed for wall flush-mounting</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd50cr-clean-room-logger-transmitter/">HD50CR &#8211; Clean Room Logger Transmitter</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>HD50CR </strong>is the ideal solution for monitoring of differential pressure, temperature and humidity in Clean Room applications.</p>
<p>A <strong>low pressure sensor</strong> with high accuracy and stability and <strong>auto-zeroing</strong> feature ensure high accuracy and stability over the time.</p>
<p>Three 0…5/10 V and 0/4…20 mA analog outputs and a digital RS485 output with <strong>“Slave” Modbus-RTU </strong>protocol allow connecting the instrument to a network of sensors are available. The instrument can also be connected to a local network via the <strong>Ethernet</strong> interface (optionally Wi-Fi, on request). The simultaneous operation of two communication protocols (proprietary and <strong>Modbus TCP/IP</strong>) is possible. The instrument manages up to 10 “TCP/IP Client” simultaneously. If the local network is connected to Internet, the data can be regularly sent to an <strong>FTP</strong> address, to the <strong>Cloud</strong> and via <strong>e-mail</strong>.</p>
<p>The instrument is also available in a version with only the 3 analogue outputs and the RS485 digital output, with decimal resolution. <strong><a href="https://environmental.senseca.com/wp-content/uploads/document/umn_prd_HD50CR-AS_en_manual.pdf">Click here for the HD50CR-AS dedicated manual.</a></strong></p>
<p>Configuring the instrument is very simple: if both connected to the same network, this can be done through any device that has been granted access to the instruments <strong>webserver</strong>.</p>
<p>For each detected quantity, two alarm thresholds can be set by the user. Exceeding a threshold is signaled by <strong>direct alarms.</strong></p>
<p>For specific FDA regulations that can apply in the Pharmaceutical industry, we can provide optional modules to our standard HD35AP-S and HDServer1 software to fully operate conform <strong>21 CFR part 11</strong> regulations.</p>
<p>The HD50CR provides the ideal solution for the application, keeping track of any out of range values and providing the perfect evidence for any quality audit. The <strong>stainless steel flush-mounted</strong> style guarantees that the instrument is easy to clean.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd50cr-clean-room-logger-transmitter/">HD50CR &#8211; Clean Room Logger Transmitter</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>