<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>monoaxial accelerometer Archives - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-tag/monoaxial-accelerometer/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-tag/monoaxial-accelerometer/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Mon, 22 Mar 2021 11:31:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.7</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>monoaxial accelerometer Archives - Senseca</title>
	<link>https://environmental.senseca.com/product-tag/monoaxial-accelerometer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HDWBV-100 &#8211; IEPE Triaxial Accelerometer &#8211; 1000 mV/g</title>
		<link>https://environmental.senseca.com/product/hdwbv-100-iepe-triaxial-accelerometer-1000-mv-g/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 20 Aug 2019 13:43:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10426</guid>

					<description><![CDATA[<p>Triaxial accelerometer for whole body measurement, ICP, 1V/g, weight 50g, range 5 g pk</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdwbv-100-iepe-triaxial-accelerometer-1000-mv-g/">HDWBV-100 &#8211; IEPE Triaxial Accelerometer &#8211; 1000 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>IEPE <strong>tri-axial accelerometer</strong> for the measurement of <strong>vibration</strong> transmitted to <strong>whole body</strong>.</p>
<p>Using the mounting kit (included) the accelerometer can be used in combination with both HD2030PAD seat adapter and <a href="https://environmental.senseca.com/product/hd2030ac5-floor-adapter-for-seismic-accelerometers/">HD2030AC5</a> floor measurement adapter.</p>
<ul>
<li>Sensitivity 1 V/g</li>
<li>Range ±5 g pk</li>
<li>Weight 50 g</li>
<li>Threaded hole 10-32 UNF</li>
<li>Connector M5 4 pin</li>
</ul>
<p>It includes:</p>
<ul>
<li>Mounting Kit for HD2030PAD and <a href="https://environmental.senseca.com/product/hd2030ac5-floor-adapter-for-seismic-accelerometers/">HD2030AC5</a>;</li>
<li>Mounting screw 10-32 UNF copper-beryllium alloy (HD6200).</li>
</ul>
<p>Accelerometer can be connected to the right input (tri-axial) of analyzer with cable<a href="https://environmental.senseca.com/product/hd2030cab3-serie-3-axis-accelerometers-connecting-cable/"> HD2030CAB3M-xxM</a> (not included).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdwbv-100-iepe-triaxial-accelerometer-1000-mv-g/">HDWBV-100 &#8211; IEPE Triaxial Accelerometer &#8211; 1000 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HDP356B18 &#8211; IEPE Triaxial Accelerometer &#8211; 1000 mV/g</title>
		<link>https://environmental.senseca.com/product/hdp356b18-iepe-triaxial-accelerometer-1000-mv-g/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 20 Aug 2019 13:23:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10424</guid>

					<description><![CDATA[<p>Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdp356b18-iepe-triaxial-accelerometer-1000-mv-g/">HDP356B18 &#8211; IEPE Triaxial Accelerometer &#8211; 1000 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>High sensitivity ICP<strong> tri-axial accelerometer</strong> for the <strong>measurement of vibrations in buildings</strong>.</p>
<ul>
<li>Sensitivity 1 V/g</li>
<li>Range ±5 g pk</li>
<li>Weight 25 g</li>
<li>10-32 UNF threaded hole ¼-28</li>
<li>4-pin connector</li>
</ul>
<p>It includes:</p>
<ul>
<li>10-32 UNF copper-beryllium alloy mounting screw (081B05);</li>
<li>M6 copper-beryllium alloy mounting screw (M081B05);</li>
</ul>
<p>The accelerometer is connected to the right input (tri-axial) of the analyzer through the <a href="https://environmental.senseca.com/product/hd2030cab3-serie-3-axis-accelerometers-connecting-cable/">HD2030CAB3-xxM</a> cable (not included).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdp356b18-iepe-triaxial-accelerometer-1000-mv-g/">HDP356B18 &#8211; IEPE Triaxial Accelerometer &#8211; 1000 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HDP356A02 &#8211; IEPE Triaxial Accelerometer &#8211; 10 mV/g</title>
		<link>https://environmental.senseca.com/product/hdp356a02-iepe-triaxial-accelerometer-10-mv-g/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 20 Aug 2019 13:01:01 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10421</guid>

					<description><![CDATA[<p>Triaxial accelerometer miniature for hand-arm measurement, ICP, 10mV/g, weight 4g, range 500 g pk</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdp356a02-iepe-triaxial-accelerometer-10-mv-g/">HDP356A02 &#8211; IEPE Triaxial Accelerometer &#8211; 10 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>ICP <strong>tri-axial accelerometer</strong> for the measurement of the <strong>vibrations</strong> transmitted to the <strong>hand-arm system</strong>.</p>
<ul>
<li>Sensitivity 10 mV/g</li>
<li>Range ±500 g pk</li>
<li>Weight 10.5 g</li>
<li>10-32 UNF threaded hole ¼-28</li>
<li>4-pin connector</li>
</ul>
<p>It includes:</p>
<ul>
<li>10-32 UNF copper-beryllium alloy mounting screw (081B05);</li>
<li>M6 copper-beryllium alloy mounting screw (M081B05);</li>
</ul>
<p>The accelerometer is connected to the right input (tri-axial) of the analyzer through the <a href="https://environmental.senseca.com/product/hd2030cab3-serie-3-axis-accelerometers-connecting-cable/">HD2030CAB3-xxM</a> cable (not included).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdp356a02-iepe-triaxial-accelerometer-10-mv-g/">HDP356A02 &#8211; IEPE Triaxial Accelerometer &#8211; 10 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HDP352C34 &#8211; IEPE Monoaxial Accelerometer &#8211; 100 mV/g</title>
		<link>https://environmental.senseca.com/product/hdp352c34-iepe-monoaxial-accelerometer-100-mv-g/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 20 Aug 2019 12:44:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=10416</guid>

					<description><![CDATA[<p>Monoaxial accelerometer general purpose, ICP, 100mV/g, weight 5,8 g, range 50 g pk</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdp352c34-iepe-monoaxial-accelerometer-100-mv-g/">HDP352C34 &#8211; IEPE Monoaxial Accelerometer &#8211; 100 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>General purpose ICP mono-axial accelerometer.</p>
<ul>
<li>Sensitivity 100 mV/g</li>
<li>Range ±50 g pk</li>
<li>Weight 5.8 g</li>
<li>10-32 UNF threaded hole</li>
<li>10-32 connector</li>
</ul>
<p>It includes:</p>
<ul>
<li>10-32 UNF copper-beryllium alloy mounting screw (081B05);</li>
<li>M6 copper-beryllium alloy mounting screw (M081B05);</li>
</ul>
<p>The accelerometer is connected to the left input (mono-axial) of the analyzer through the <a href="https://environmental.senseca.com/product/hd2030cab1-serie-low-noise-coaxial-cable/">HD2030CAB1-xxM</a> cable (not included).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hdp352c34-iepe-monoaxial-accelerometer-100-mv-g/">HDP352C34 &#8211; IEPE Monoaxial Accelerometer &#8211; 100 mV/g</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
