<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>irradiance Archives - Senseca</title>
	<atom:link href="https://environmental.senseca.com/product-tag/irradiance/feed/" rel="self" type="application/rss+xml" />
	<link>https://environmental.senseca.com/product-tag/irradiance/</link>
	<description>Member of GHM GROUP</description>
	<lastBuildDate>Wed, 20 May 2026 15:14:17 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.8</generator>

<image>
	<url>https://environmental.senseca.com/wp-content/uploads/2023/12/favicon-senseca-180x180-1-100x100.png</url>
	<title>irradiance Archives - Senseca</title>
	<link>https://environmental.senseca.com/product-tag/irradiance/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LPUVA02 &#8211; Radiometric Probe for Irradiance</title>
		<link>https://environmental.senseca.com/product/lpuva02-radiometric-probe-for-irradiance-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:42:04 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lpuva02-radiometric-probe-for-irradiance-2/</guid>

					<description><![CDATA[<p>Amplified radiometric probe for outdoor use for measuring IRRADIANCE in the UVA spectral range (315...400 nm).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuva02-radiometric-probe-for-irradiance-2/">LPUVA02 &#8211; Radiometric Probe for Irradiance</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for outdoor use for measuring <strong>IRRADIANCE in the UVA spectral range (315&#8230;400 nm)</strong>.  Supplied with Calibration Report. On request CPM12AA4… cables with 4-pole M12 connector.</p>
<p>The LPUVA02 radiometer measures the broadband UVA irradiance on a plane surface (Watt/ m²). Measured irradiance is the result of the sum of direct solar<br />
irradiance and of diffuse irradiance. TIt can measure as well the UVA irradiance in closed room.</p>
<p>The radiometer is produced in three versions:</p>
<ul>
<li><strong>LPUVA02</strong> &#8211; passive &#8211; μV per μW/cm² output;</li>
<li><strong>LPUVA02AC</strong> &#8211; active, 4&#8230;20 mA current output</li>
<li><strong>LPUVA02AV</strong> &#8211; active, 0…1 Vdc, 0…5 Vdc or 0…10 Vdc output (0…150 W/m²)</li>
</ul>
<p>The irradiance range for the analog output is 0…200 W/m².<br />
Each radiometer is individually calibrated at the factory and is distinguished by its own calibration factor. The calibration is performed by comparison with the primary standard of the Senseca metrology laboratory, using the emission line at 365 nm of a suitably filtered Xe-Hg lamp.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuva02-radiometric-probe-for-irradiance-2/">LPUVA02 &#8211; Radiometric Probe for Irradiance</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HD2302.0 &#8211; Portable Luxmeter</title>
		<link>https://environmental.senseca.com/product/hd2302-0-portable-luxmeter-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/hd2302-0-portable-luxmeter-2/</guid>

					<description><![CDATA[<p>Portable luxmeter for measuring illuminance, luminance, PAR, irradiance</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd2302-0-portable-luxmeter-2/">HD2302.0 &#8211; Portable Luxmeter</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Portable luxmeter for measuring <strong>illuminance, luminance, PAR, irradiance</strong> (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).</p>
<p>Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.</p>
<p>LP471 series probes with SICRAM module are suitable.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/hd2302-0-portable-luxmeter-2/">HD2302.0 &#8211; Portable Luxmeter</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471RAD &#8211; Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471rad-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471rad-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the spectral range 400nm...1050nm, cosine correction diffuser.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471rad-irradiance-probe-2/">LP471RAD &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the spectral range 400 nm…1050 nm, cosine correction diffuser.</p>
<p>Measuring range: 1.0·10-³ W/m²…2000 W/m².</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471rad-irradiance-probe-2/">LP471RAD &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471UVA &#8211; UVA Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471uva-uva-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uva-uva-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the UVA spectral range 315nm...400nm, peak at 360nm, quartz diffuser for cosine correction</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uva-uva-irradiance-probe-2/">LP471UVA &#8211; UVA Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the <strong>UVA</strong> spectral range 315 nm…400 nm, peak at 360 nm, quartz diffuser for cosine correction. For non-destructive testing ISO 3059:2001, EN 571-1, ASTM E1417.</p>
<p>Measuring range: 1 mW/m² … 2000 W/m².</p>
<p>Cable length 2 m.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uva-uva-irradiance-probe-2/">LP471UVA &#8211; UVA Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471UVB &#8211; UVB Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471uvb-uvb-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uvb-uvb-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the UVB spectral range 280nm...315nm, peak at 305nm, quartz diffuser for cosine correction</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvb-uvb-irradiance-probe-2/">LP471UVB &#8211; UVB Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the UVB spectral range 280 nm…315 nm, peak at 305 nm, quartz diffuser for cosine correction.</p>
<p>Measuring range: 1 mW/m² … 2000 W/m².</p>
<p>Cable length 2 m.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvb-uvb-irradiance-probe-2/">LP471UVB &#8211; UVB Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471UVC &#8211; UVC Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471uvc-uvc-irradiance-probe-2/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Mon, 05 Oct 2020 13:41:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471uvc-uvc-irradiance-probe-2/</guid>

					<description><![CDATA[<p>Radiometric probe for measuring the IRRADIANCE in the UVC spectral range 220 nm...280 nm</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvc-uvc-irradiance-probe-2/">LP471UVC &#8211; UVC Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Radiometric probe for measuring the <strong>IRRADIANCE</strong> in the <strong>UVC</strong> spectral range 220 nm…280 nm, peak at 260 nm, quartz diffuser for cosine correction.</p>
<p>Measuring range: 1 mW/m² … 2000 W/m².</p>
<p>Cable length 2 m.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471uvc-uvc-irradiance-probe-2/">LP471UVC &#8211; UVC Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPUVB01 &#8211; Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lpuvb01-irradiance-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 12 Dec 2018 13:08:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=9783</guid>

					<description><![CDATA[<p>Probe for measuring irradiance in the UVB (280 nm ...315 nm) spectral range</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuvb01-irradiance-probe/">LPUVB01 &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>LPUVB01</strong> probe measures irradiance (W/m<sup>2</sup>) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m<sup>2</sup>) in the UVB (280 nm &#8230;315 nm) spectral range.</p>
<p>Thanks to a new type of photodiode, LPUVB01 is blind to visible and infrared light. Probe calibration is carried out by using a 313 nm line of a Xe-Hg lamp, filtered through a special interferential filter.</p>
<p>Measurement is carried out by comparison with the primary standards, assigned to <a href="https://environmental.senseca.com/calibrations/light/">Senseca Metrological Laboratory.</a></p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuvb01-irradiance-probe/">LPUVB01 &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LPUVA01 &#8211; Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lpuva01-irradiance-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Wed, 12 Dec 2018 13:01:16 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/?post_type=product&#038;p=9782</guid>

					<description><![CDATA[<p>Probe for measuring irradiance in the UVA (315 nm ... 400 nm) spectral range</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuva01-irradiance-probe/">LPUVA01 &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>LPUVA01</strong> probe measures irradiance (W/m<sup>2</sup>) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m<sup>2</sup>) in the UVA (315 nm &#8230; 400 nm) spectral range.</p>
<p>Thanks to a new type of photodiode, LPUVA01 is blind to visible and infrared light.</p>
<p>Probe calibration is carried out by using a 365 nm line of a Xe-Hg lamp, filtered through a special interferential filter. Measurement is carried out by comparison with the primary standards, assigned to <a href="https://environmental.senseca.com/calibrations/light/">Senseca Metrological Laboratory</a>.<br />
This probe can be used in all processes where ultraviolet lamp emission needs to be monitored: resins and adhesives polymerization, as well as tanning lamps.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lpuva01-irradiance-probe/">LPUVA01 &#8211; Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471P-A &#8211; Combined Illumincance and Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471p-a-illumincance-and-irradiance-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 31 Jul 2018 14:43:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471p-a-illumincance-and-irradiance-probe/</guid>

					<description><![CDATA[<p>Combined probe for measuring the ILLUMINANCE (lux), with standard photopic spectral response, and for measuring the IRRADIANCE (W/m²) in the UVA spectral range (315-400 nm, with peak at 365 nm).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471p-a-illumincance-and-irradiance-probe/">LP471P-A &#8211; Combined Illumincance and Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Combined probe for measuring <strong>ILLUMINANCE</strong> (lux), with standard photopic response, and <strong>IRRADIANCE</strong> (μW/cm²) in the UVA spectral range (315&#8230;400 nm, with peak at 360 nm).</p>
<p>Both the sensors are equipped with diffuser for the correction according to the cosine law.</p>
<ul>
<li>Illuminance measuring range: 0.10 lux … 200·10³ lux.</li>
<li>Irradiance measuring range: 1.0 mW/m² … 2000 W/m².</li>
</ul>
<p>This probe provides the ratio between UVA irradiance and illuminance in μW/lumen (quantity of interest in museums). CIE 157.</p>
<p>Supplied with SICRAM module and 2 m cable.</p>
<p>The probe works with the instruments <a href="https://environmental.senseca.com/product/do9847-all-measurements-3-channel-portable-data-logger/">DO9847</a> (from rev. R.1), <a href="https://environmental.senseca.com/product/hd31-handheld-portable-multifunction-data-logger/">HD31</a>, <a href="https://environmental.senseca.com/product/hd2302-0-portable-luxmeter/">HD2302.0</a> (from rev. 01), <a href="https://environmental.senseca.com/product/hd2102-1-portable-luxmeter/">HD2102.1</a> (from rev. 11) and <a href="https://environmental.senseca.com/product/hd2102-2-portable-luxmeter-data-logger/">HD2102.2</a> (from rev. 21).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471p-a-illumincance-and-irradiance-probe/">LP471P-A &#8211; Combined Illumincance and Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LP471A-Uveff &#8211; Total Effective Irradiance Probe</title>
		<link>https://environmental.senseca.com/product/lp471a-uveff-total-effective-irradiance-probe/</link>
		
		<dc:creator><![CDATA[Senseca]]></dc:creator>
		<pubDate>Tue, 31 Jul 2018 14:43:26 +0000</pubDate>
				<guid isPermaLink="false">https://www.deltaohm.com/product/lp471a-uveff-total-effective-irradiance-probe/</guid>

					<description><![CDATA[<p>Combined probe for measuring the total effective irradiance according to the weighting curve UV.</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471a-uveff-total-effective-irradiance-probe/">LP471A-Uveff &#8211; Total Effective Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The combined probe LP471A-UVeff measures the <strong>Total Effective Irradiance</strong> (W/m²) weighted according to the UV action curve (CEI EN 60335-2-27).</p>
<p>The probe is made of two sensors, the signals of the sensors are combined and weighted to obtain an accurate spectral response. The two probes are equipped with a diffuser for the correct measure according to the cosine law.</p>
<p>The probe provides the following data:</p>
<ul>
<li><strong>Total Effective Irradiance (E<sub>eff</sub>)</strong> &#8211; Measuring range: 0.01 W/m²…20 W/m².</li>
<li><strong>Effective Irradiance in the range UV-CB</strong> &#8211; Measuring range: 0.01 W/m²…20 W/m²</li>
<li><strong>Irradiance in the UVA spectrum</strong> &#8211; Measuring range: 0.1 W/m²…2000 W/m²</li>
</ul>
<p>When used for the control of cosmetic tanning systems, with the LP471A-UVeff  it is easy to determine the exposure time for the first session (set to  100J/m² effective) and the total time per year (maximum dose limit established is 15kJ/m² per year). Alternatively you can calculate the dose received per session. You can also check the status of lamps aging by regularly measuring the solarium emission.</p>
<p>Supplied with SICRAM module and 2 m cable.</p>
<p>The probe works with the instruments: <a href="https://environmental.senseca.com/product/do9847-all-measurements-3-channel-portable-data-logger/">DO9847</a> (from rev. R.1), <a href="https://environmental.senseca.com/product/hd31-handheld-portable-multifunction-data-logger/">HD31</a>, <a href="https://environmental.senseca.com/product/hd2302-0-portable-luxmeter/">HD2302.0</a> (from rev. 01), <a href="https://environmental.senseca.com/product/hd2102-1-portable-luxmeter/">HD2102.1</a> (from rev. 11) and <a href="https://environmental.senseca.com/product/hd2102-2-portable-luxmeter-data-logger/">HD2102.2</a> (from rev. 21).</p>
<p>The post <a rel="nofollow" href="https://environmental.senseca.com/product/lp471a-uveff-total-effective-irradiance-probe/">LP471A-Uveff &#8211; Total Effective Irradiance Probe</a> appeared first on <a rel="nofollow" href="https://environmental.senseca.com">Senseca</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
